User Interfaces - Grundfos CRE Installation And Operating Instructions Manual

E-pumps with mle frequency-controlled permanentmagnet motors
Table of Contents

Advertisement

8. Route the wires for the CIM module. See the example in the
figure below.
Example of wire routing
9. Fit the CIM cover.
10. If the CIM module is supplied with an FCC label, then place this
on the terminal box. See the figure below.
FCC label
11. Fit the terminal box cover (figure Removing the terminal box
cover above, B) and cross-tighten the four mounting screws (A)
to 6 Nm.
Make sure that the terminal box cover is aligned with
the operating panel. See the section on changing the
position of the operating panel.
Related information
5.8 Changing the position of the control (operating) panel
20

7. User interfaces

You can make the pump settings by means of the following user
interfaces:
Operating panels
Remote controls
If the power supply to the pump is switched off, the settings are
stored.
Related information
7.1 Standard operating panel
7.2 Advanced operating panel
7.3 Grundfos GO Remote
7.4 R100 remote control
FCC
WARNING
Hot surface
Death or serious personal injury
Only touch the buttons on the display as the product
may be very hot.
Standard operating panel. See the section on the
standard operating panel.
Advanced operating panel. See the section on the
advanced operating panel.
Grundfos GO Remote. See the section on Grundfos
GO Remote.
Grundfos R100 remote control. See the section on R100 remote
control.

Advertisement

Table of Contents
loading

This manual is also suitable for:

CrieCrneCrkeSpkeMtreCme

Table of Contents