Epson WF-5690/4640/4630/5620/5190/5110 series

3.2.3 Head Angular Mechanism adjustment.

This section describes the procedure for the Head angular mechanism adjustment.

3.2.3.1 Preparation of the Head Angular Adjustment

 When the Head angular adjustment is performed, it is necessary to remove the ADF/SCN
unit and the exterior parts from the product.
However, the fatal error occurs if the ADF/SCN unit is removed from product, and the
printer is turned on.
Therefore, make sure to start the printer by the printer inspection mode when the Head
angular adjustment is performed.
 In case of the WF-5190/5110 series, turn on them as usual because ADF/SCN unit is not
supported for them.
During the Inspection Mode, operations such as menu selection can be done by pressing the
following buttons on the panel.
 Start operation of Printer Inspection Mode
1. Connect the Panel Unit and the Cover open sensor to the Main Board in the condition that ADF/SCN
Unit and exterior parts are removed.
(Make sure to fix the cover open sensor with the tape to deactivate the cover open error.)
Adjustment
Power
Figure 3-3. Panel Operation in Inspection Mode
Panel Unit
Figure 3-4. Preparation of the Head Angular Adjsutment (1)
Details of Adjustments
【3】
Moves up menu selection.
【Color】
Enter
Cover Open Sensor
Revision D
【6】
Moves down menu selection.
Confidential