Epson WF-5690/4640/4630/5620/5190/5110 series

3.2.5 Checking the Platen Gap

This section describes the procedure for checking the platen gap (PG) necessary when removing the Printhead or
in a similar case.
When checking the PG, make sure of the following.
 Move the Carriage Assy by pulling the Timing Belt.
 Be careful not to damage the nozzle surface of the Printhead with the thickness gauge.
Tools
 Thickness gauge: 1.37 mm (x2), 1.47 mm (x2)
 Teflon Tape: Commercial item (thickness: 0.08 mm)
Checking procedure
1. Check the PG position is set to PG 1. (See
2. Move the Carriage Assy to the center of the printer.
3. Place the thickness gauges (1.37 mm) on the positions shown in
4. Pull the Timing Belt to move the Carriage Assy to both ends and confirm the Carriage Assy does not touch
the thickness gauges. If the Carriage Assy comes in contact with the thickness gauges, the PG is narrower
than the standard value, therefore, perform
5. Move the Carriage Assy to the center, and replace the thickness gauges (1.37 mm) with the thickness gauges
(1.47 mm) on the same positions as
6. Pull the Timing Belt to move the Carriage Assy to both ends and confirm the Carriage Assy touches the
thickness gauges. If the Carriage Assy does not come in contact with the thickness gauges, the PG is wider
than the standard value, therefore, perform
Adjustment
"Preparation
(p68)".)
"3.2.3 Head Angular Mechanism adjustment.
Step 3.
"3.2.3 Head Angular Mechanism adjustment.
Details of Adjustments
Figure 3-25 (p
72).
Revision D
(p60)".
(p60)".