6 | Electrical connection
Color coding of the terminals
Connection
Phase
Protective conduc-
tor
6.5
Connect the device for demo mode to the power grid
The demo mode is used for demonstration purposes for the basic functions of
the device.
Observe the following table with the color codings for the connection.
Color coding of the terminals for demo mode
Power supply for demo mode
A power supply of at least 190 V – 240 V AC 50 / 60 Hz is required to run
demo mode.
Connection
Phase
Neutral conductor
Protective conduc-
tor
The following functions are activated or deactivated in demo mode:
Cooking processes are simulated (processes are speeded up)
n
Movement of the pan and device cover is active
n
Heating is deactivated
n
If the device is connected in demo mode, the following connections are suffi-
cient:
One phase
n
One neutral conductor
n
One protective conductor
n
Equipotential bonding
n
6.6
Closing the electrical compartment
a
The power cable is connected to the device.
34 / 52
Conductor color
Black, red and beige
Green
NOTE
Conductor color
Black
White
Green
80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US
Terminal
L1, L2, L3
PE
Terminal
L1
L2
PE
Tool
Hex key
Slotted screwdriver
Tool
Hex key
Hex key
Slotted screwdriver