® iVario 2-XS ® iVario Pro 2-S Original installation instructions...
Page 2
Device hand-over Dealer: Installer: Include the following information with queries: Device type: Device no.: Your device was tested by (name): WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
Table of contents 1 Introduction ......................... 5 Information on this manual ...................... 5 Target audience.......................... 5 Copyright ............................ 6 Conformity ............................ 6 Liability and warranty conditions ................... 6 Identification of the device ....................... 7 2 Safety........................... 10 Display of warning notices .................... 10 General safety information .................... 10 Intended use..........................
Page 4
Placing the device on the stand.................... 27 Fixing the device in place ....................... 28 6 Electrical connection .................... 29 Regulations for the electrical connection ................ 29 Opening the electrical compartment.................. 30 Connecting the equipotential bonding ................ 33 Connecting the device to the power grid................ 33 Connect the device for demo mode to the power grid ..........
The manual enables safe handling of the unit and correct installation. The images in this manual are examples only and may differ from the device. This manual is valid for the following devices: iVario 2-XS iVario Pro 2-S Storage Keep the installation manual and operating manual with the unit.
1 | Introduction Copyright It is not permitted to pass on product-specific information to third parties. We reserve the right to implement technical developments and changes in the in- terest of progress. All rights are reserved, including those of translation and re- production.
1 | Introduction Identification of the device Type plate The type plate is located behind the left pan on the installation box. The type plate includes the following information: 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 7 / 52...
Page 8
1 | Introduction Marketing name Model number Connection voltage Frequency Connected load Breaker Cable diameter Information on the motor (with floor units only) Pressure (only with pressure option) WiFi connectivity Permissible water pressure Serial number Device type and model number The assignment can be found in the table below.
Page 9
1 | Introduction Device size type plate Unit size LMX.100AE … iVario 2-XS LMX.100BE … iVario Pro 2-S LMX.200BE … iVario Pro 2-S with print option 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 9 / 52...
2 | Safety Safety Display of warning notices DANGER Type and source of danger Failure to observe these warnings will result in severe injuries or death. Measures to avoid the danger WARNING Type and source of danger Failure to observe these warnings could result in severe injuries or death. Measures to avoid the danger CAUTION Type and source of danger...
2 | Safety The device should only be set up in a protected environ- ment safe from frost and wind. Do not set up the device in adverse weather conditions, such as rain. The device should only be connected in accordance with the installation manual and the information on the type plate.
3 | Product description Product description Device description NOTE Never seal or pipe the safety overflow Do not reduce the cross-section of the safety overflow. The safety overflow but be accessible and clear at all times. It is used for ventilation and as a drain in the event of blockages.
The sound emission value is below 70 dB. 3.2.1 Device weight Unit size Weight without packaging kg Weight with packaging kg [lbs] [lbs] iVario 2-XS 117 [258] 144 [317] iVario Pro 2-S 134 [295] 161 [355] iVario Pro 2-S with...
1250 [49 1/4] 1100 [43 1/4] 675 [26 5/8] 3.2.3 Pan dimensions Usable capacity Unit size Useful volume l [gal] iVario 2-XS 17 [4,5] iVario Pro 2-S 25 [6,5] Pan internal dimensions Unit size Width mm [inch] x Depth mm [inch] y...
Page 15
3 | Product description Unit size Thermal load latent (kJ/h) Thermal load sensi- tive (kJ/h) iVario Pro 2-S 20866 4309 We reserve the right to implement technical developments and changes. 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 15 / 52...
4 | Transport Transport CAUTION Risk of crushing due to the weight of the device Hands, fingers and feet may be crushed. Wear suitable protective clothing during transport. Use lifting aids such as lifting straps. CAUTION Risk of tipping during transport Risk of crushing if the device tips over onto a person.
Ensure that the weight of the device is distributed evenly. Note the center of gravity of the device. Width mm [inch] x Depth mm [inch] y Height mm [inch] z iVario 2-XS 544 [21 3/8] 176 [6 7/8] 155 [6 1/8] iVario Pro 2-S...
4 | Transport Lifting points on the unit 1. Lift the unit on the base frame marked in the figure and on the marked pan paneling. Transport with pallet The packaging material is removed. The device is on the transport pallet. 1.
4 | Transport 2. Lift the device off the transport pallet on the lifting points and set it down on the designated installation surface. >> The device is set down on the designated installation surface and ready for setup and installation. Transport without pallet with lift truck NOTE Transport with transport aid without protection...
4 | Transport 2. Lift the device off the pallet on the lifting points and set it down on the lift truck. >> The device is set down on the designated installation surface and ready for setup and installation. Vertical transport without pallet with lift truck CAUTION Risk of crushing and injury during vertical transport without straps The pan covers can open during vertical transport.
Page 21
4 | Transport 2. Transport the unit to the installation site slowly with the lift truck. Hold the unit securely during transport. 3. Lift the unit on the lifting points and place it on the designated installation surface. 4. Remove the fixing straps. >>...
5 | Setup Setup CAUTION Risk of crushing during setup Fingers, hands and feet may be crushed under the device. Wear suitable protective clothing during setup. Only lift the device via the designated lifting points. Requirements When setting up the device on a stand, ensure that only genuine stands from the device manufacturer are used.
5 | Setup Manufacturer recommendation 1. Set up the device with a minimum distance of 50 mm [2 inch] from the wall at the left and right to enable ideal cleaning of the device. 50 mm 50 mm [2 inch] [2 inch] 5.1.2 Distance from heat sources NOTE...
5 | Setup 350 mm [14 Inch] 350 mm 350 mm [14 Inch] [14 Inch] 500 mm [20 Inch] 500 mm 500 mm [20 Inch] [20 Inch] 5.1.3 Distance from water sources WARNING Risk of burning if the minimum distances from open water sources is not observed Water can spray into the hot pan, in hot liquids or in hot fat.
Page 25
5 | Setup Set up the device with a minimum distance of 900 mm [35 3/8 inch]. If you can not observe the distance, install the non-flammable divider as described in this manual. 1. Set up the device with a minimum distance of 900 mm [35 3/8 inch] from open water sources.
5 | Setup Setting up the device CAUTION Risk of tipping when setting up on the installation surface Risk of crushing if the device tips over onto a person. Note the center of mass of the device. Ensure that the device does not tip over during lifting. The installation surface is horizontal.
5 | Setup 2. Place a spirit level on the right pan and align the unit horizontally using both unit feet. 3. Place a spirit level on the left pan and align the unit horizontally using both unit feet. 4. Check that both pans are aligned horizontally. >>...
5 | Setup The stand is aligned horizontally. The minimum distances are observed. 1. Position the device feet on the bolt of the stand. >> The device is positioned on the stand and secured against slipping. Fixing the device in place The manufacturer recommends fixing the device to the installation surface.
6 | Electrical connection Electrical connection DANGER High voltages during connection to the power grid Danger to life when working with high voltage. Disconnect the connection from the power supply. Ensure that the unit is de-energized. DANGER Electric shock due to incorrect connection There is a danger to life if the cable conductors are connected incorrectly.
6 | Electrical connection Notes The cross-sections of the connection cables are based on the power con- sumption and local regulations. Color coding of the conductors Observe the color coding of the conductors and country-specific deviations. Color of the conductor Function of the conductor Green Protective conductor...
Page 31
6 | Electrical connection NOTE Damage to the holes for the electrical cabinet cover Failure to follow the order for removing and tightening the screws for the electrical compartment cover could result in damage to the holes due to the preload in the cover.
Page 32
6 | Electrical connection 3. Press lightly on the cover in the area of the relevant screw and release the screws (1) and (2). 4. Loosen the screws (3),(4), (5) and (6) one after the other. 5. Remove the cover on the electrical compartment. >>...
6 | Electrical connection Connecting the equipotential bonding 1. Connect the equipotential bonding before installing the connections. Connecting the device to the power grid Notes on the power cable and connection point The manufacturer recommends using a flexible power cable. A rigid power cable makes the connection more difficult and can impact the position of the device.
6 | Electrical connection Color coding of the terminals Connection Conductor color Terminal Tool Phase Black, red and beige L1, L2, L3 Hex key Protective conduc- Green Slotted screwdriver Connect the device for demo mode to the power grid The demo mode is used for demonstration purposes for the basic functions of the device.
Page 35
6 | Electrical connection 1. Place the cover on the electrical compartment. 2. Insert the screws. 3. Tighten the screws (1), (2), (3) and (4) one after the other. 4. Insert the screws (5) and (6). 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 35 / 52...
The device can be used with frequencies of 50 Hz and 60 Hz without tech- nical modifications. 3 AC 440 V Power kW Power consump- Fuse A Conductor cross-sec- tion A tion AWG iVario 2-XS iVario Pro 2-S 3 AC 208 V Power kW Power consump- Fuse A Conductor cross-sec- tion A tion AWG...
6 | Electrical connection 3 AC 240 V Power kW Power consump- Fuse A Conductor cross-sec- tion A tion AWG iVario 2-XS iVario Pro 2-S 3 AC 480 V Power kW Power consump- Fuse A Conductor cross-sec- tion A tion AWG...
Page 38
6 | Electrical connection > The dip switch is located on the I/O board A10 close to the transformer. 3. The switch position according to the supply voltage can be found in the ta- ble below. > The dip switch is set to the supply voltage 3 AC 208 V as standard in the basic settings.
6 | Electrical connection 4. Use the control panel to select the service level. Navigate to Options (1) and switch to the relevant supply voltage (2). 5. Switch the unit off and on again. The changes will now be applied. 6.
Page 40
6 | Electrical connection 3. Switch the unit on. 4. Run a performance check. Verify that the measured performance data matches the setting. >> The power supply has been successfully switched. 40 / 52 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US...
The WLAN adapter integrated in the device is a market-dependent option that is not available in every country. For devices from the iVario 2-XS series, WLAN is available as an option. The devices from the iVario Pro 2-S series have WLAN as standard.
8 | Water connection Water connection Regulations for water connection NOTE Connection to soft water When connecting the device to soft water, ensure that the water has a residual hardness of at least 4 °dH. A soft water connection is not required. Water pipe Use a separate tap for each device on-site.
Page 43
8 | Water connection 1. Connect the water hose to the water inlet for the device. 2. Open the tap. >> The water inlet is connected. 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 43 / 52...
9 | Waste water connection Waste water connection Regulations for the wastewater connection NOTE Drain pipe does not comply with the regulations Use a steam temperature resistant drain pipe that at least corresponds to a pipe of type PP. Do not use a hose. NOTE Contaminated wastewater and wastewater containing grease Ensure that a grease separator is installed on-site to treat the wastewater.
9 | Waste water connection Connecting the wastewater drain The wastewater connection is located on the rear side of the device. Diameter on the device drain: DN 40 mm Installing the wastewater connection with drain to the rear side of the device The drain pipe is designed for a DN 40 mm device drain.
Page 46
9 | Waste water connection 4. When installing the device on a genuine stand, feed the drain pipe through the gap in the stand. 5% / 3° 5. Observe a minimum distance of 20 mm [3/4 Inch] between the drain channel and waste water drain.
Page 47
9 | Waste water connection 6. When connecting the drain pipe in the wall, the installation altitude must be between 150–300 mm [5 7/8–11 3/4 inch]. 150–300 mm 5 7/8–11 3/4 Inch 7. Position the cover and screw in the 2 screws. >>...
Page 48
9 | Waste water connection 1. Insert the mounting clip in the gaps in the adjustable foot. 2. Connect the drain pipe DN 40 mm with a constant incline of at least 5 % or 3° and route it through the mounting clip to the front side of the device. 3.
Page 49
9 | Waste water connection 4. When installing the device on a genuine stand, the drain pipe can be fixed to the stand with a bracket. >> The drain pipe is installed with an incline of at least 5 % or 3° with the drain to the front.
10 | Decommissioning Decommissioning 10.1 Notes on decommissioning Observe the following when decommissioning the device: Ensure that the device is disconnected from the power supply and is de- energized. Remove all water and wastewater connections from the device. If the device is to be transported, remove the device from the foot locking mechanisms and from any wall mountings (mounting chain).
Options 11.1 Setup options The device can be set up with the following options and ordered from the man- ufacturer under the following item numbers: Unit size iVario 2-XS iVario Pro 2-S Stand with feet 60.31.221 60.31.319 Stand with castors 60.31.317...
Page 52
RATIONAL AG Siegfried-Meister-Straße 1 86899 Landsberg am Lech, Germany Tel. +49 (0)8191 3270 Fax +49 (0)8191 21735 info@rational-online.com rational-online.com RATIONAL Wittenheim SAS 4 Rue de la Charente F-68270 Wittenheim Tel. +33 389 570 135 Fax. +33 389 570 136 info@rational-online.com rational-online.com...
Need help?
Do you have a question about the iVario 2-XS and is the answer not in the manual?