Heat Types - IBC EBX Series Installation And Operation Manual

Residential electric boiler
Table of Contents

Advertisement

Summer Shutdown
range: 50°F to 104°F (10°C to 40°C)
default: 65°F (18.3°C)
Status is ON in ODR mode
Post-Purge Time: pump will run set number of seconds after a call
3. Status Menu
Outlet [Temperature]
Inlet [Temperature]
Outdoor [Temperature]
Power % (current output)
Faults and Warnings:  press Enter for code with plain language description.
For warning codes see
Figure 20
Controller Status screen
The control automatically returns next higher level in 1 minute if no button has been touched.
If the controller is in an error state, the Error Code and an explanatory text will be displayed.
If the controller has a warning to declare, the screen will rotate between the Home Screen and the
Warning(s), each displayed for 10 seconds. Warnings do not prevent operation.

7.2.1 Heat Types

The EBX-series controller can be programmed for either of two Heat Types: Setpoint (SET) and
Outdoor Reset (ODR).
Note that if an outdoor sensor is connected and reports a temperature above the setting
Shutdown, the boiler will not fire: it will stay in Ready mode and report
Troubleshooting error messages on page 57
43
7.2.1 Heat Types
Summer
E3: Summer
Shutdown.