6. Operation
Work mode1: Self-Use Mode (default)
Recommended setting is Self-Use Mode.
This mode can maximize the use of PV power generation for household electricity, or
store it in batteries and use it for household electricity.
If need manually control the battery charging and discharging with respect to time,
please use the Time of Use switch and the following set points.
The "Allow Grid Charging" is recommended to be turned on (If turned off, the inverter
will not force charge the battery and battery could potentially go to sleep).
Work mode2: Feed in Priority Mode
This mode can preferentially sends power to the grid when the load is met, used in
areas where there is a subsidy for power to the grid.
If need manually control the battery charging and discharging with respect to time,
please use the Time of Use switch and the following set points.
The "Allow Grid Charging" is recommended to be turned on (If turned off, the inverter
will not force charge the battery and battery could potentially go to sleep).
Self-Use Mode
Self-Use Mode
Time of Use Switch
Time of Use Charge Current Set
Time of Use Discharge Current Set
Charge Time Slot 1
Discharge Time Slot 1
Charge Time Slot 2
Discharge Time Slot 2
Charge Time Slot 3
Discharge Time Slot 3
Allow Grid Charging
Feed in Priority Mode
Feed in Priority Mode Switch
Time of Use Switch
Time of Use Charge Current Set
Time of Use Discharge Current Set
Charge Time Slot 1
Discharge Time Slot 1
Charge Time Slot 2
Discharge Time Slot 2
Charge Time Slot 3
Discharge Time Slot 3
Allow Grid Charging
32
>
10.0A
>
10.0A
>
22:00 ~ 08:00
>
08:00 ~ 22:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00
>
20.0A
>
50.0A
>
08:00 ~ 18:00
>
19:00 ~ 08:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00
>
00:00 ~ 00:00