3.7 When the thermostat is functioning normally, a faint click is heard when the load is
switched on and off.
3.8 Ventilation mode: when thermostat notices a major decreasing in room
temperature (room is being ventilated) the load is automatically connected off for 15
minutes. After this the functioning of the thermostat becomes normal.
3.9 Self diagnostics: when the fl oor sensor is used the thermostat recognizes if the
sensor is short-circuited, cut off or missing. The fault is indicated by blinking the red
(B) and blue (C) signal lights in turn.
4. TECHNICAL DATA
ECO16FR
Supply voltage:
Switch contact:
Operating temperature range:
Temperature change:
Limitation of max temperature: +25...+50 °C
Signal light B:
Signal light C:
Floor sensor:
Floor sensor resistance values: see page 2, table 1 (sensor not connected).
Circuit breaker/fuse:
Type
ECO16FR
Thermostat can control external relay.
5. PICTURES
1 Connection diagram
2 Connection of wires to the thermostat
3 User interface of the thermostat
4 Installation and uninstallation
5 Functions of ECO16FR thermostat
6 Relation between the concrete and fl ooring material temperature
7 Temperature change
8 Limitation of adjustment range
9 Calibration of the adjustment knob
230 V -15%, +10%, 50 Hz
2-pole
-20...+30 °C
adjustable +5...-15°C, control 230V
adjustable +20...-20°C, control Ensto Smart / ECO 600
-system
green: thermostat on, heating off
red: heating on
blue: temperature change on
blue blinking: limitation of fl oor temperature on, or
ventilation on.
red and blue blinking: fl oor sensor fault
NTC, 47 kohm at 25°C, cable 4 m (extendable to 10 m)
max 16A
Temp.
Nom.current
range
(res)
5-35°C
16A
room
10-50°C
16A
fl oor
Max
Protection
load
class
3600W
IP30
3600W
15