Summary of Contents for SeaLevel DIO-32.PCIe

  • Page 1 DIO-32.PCIe User Manual | 8004e © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 2: Table Of Contents

    APPENDIX A – HANDLING INSTRUCTIONS ....................23 APPENDIX B – TROUBLESHOOTING ........................ 24 APPENDIX C – HOW TO GET ASSISTANCE ..................... 27 APPENDIX D – DRAWING..........................28 APPENDIX E – COMPLIANCE NOTICES ......................29 WARRANTY ................................ 30 © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 3: Before You Get Started

    What’s Included The 8004e is shipped with the following items. If any of these items are missing or damaged, please contact Sealevel for replacement. 8004e - DIO-32.PCIe Digital I/O Adapter • 8004e – Board with 3-13 inputs 8004He – Board with 10-30V inputs DB78 Maes to D37 Male and DB37 Female V-cable (Item# CA165) •...
  • Page 4: Introduction

    Introduction Overview The DIO-32.PCIe digital I/O interface provides 16 optically isolated inputs and 16 reed relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide high quality, long life, low current (10 Watt maximum), dry contact switch closures.
  • Page 5 Break out serial and digital connectors to screw terminals for easy field connection. The TB02 terminal block is designed with both DB37 male and female connectors for interfacing the inputs or outputs. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 6: Electrical Specifications

    Contact Resistance, Initial .15Ω Rated Life Low Load 200 Million Closures Maximum Load 100 Million Closures Contact Speed Operate .5 mS Release .5 mS Bounce .5 mS Maximum Operating Speed 600 Hz © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 7: Technical Specifications

    10 to 90% R.H. Non-Condensing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested. These printed circuit boards are solder mask over bare copper or solder mask over tin nickel. © Sealevel Systems, Inc.
  • Page 8: Hardware Installation

    Do not install the PCI Express board until the software has been fully installed. The DIO-32.PCIe does not need to be configured prior to installation. Once you have installed the SeaI/O Classic software, install the board into an available PCI Express slot and boot the computer.
  • Page 9 5. You should see the card assignment listed as ‘SeaI/O 8004e’ with the card number in parentheses. The card number will increment for each additional SeaI/O device installed. The DIO-32.PCIe is now ready for use. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 10 Digital I/O Interface The DIO-32.PCIe provides four parallel input/output (I/O) ports. The ports are organized as ports A, B, C, and D. Port A and B are input ports interfaced to optically-isolated inputs, while ports C and D are reed relay output ports.
  • Page 11: Programming The Dio-32.Pci

    Programming the DIO-32.PCI Sealevel’s SeaI/O Classic software is provided to assist in the development of reliable applications for the Sealevel Systems family of PCI and PCI Express digital I/O adapters. Included in Sealevel’s software are driver functions for use in accessing the I/O as well as helpful samples and utilities.
  • Page 12 Increasing the input resistor accordingly can increase the maximum input voltage. Because socketed DIP resistors are utilized, they can easily be replaced with a different value. Sealevel can do this, if necessary. The input circuits are not intended for monitoring 120-volt AC circuits. In addition to being too high a voltage for the circuits, it is dangerous to have that high a voltage on the card.
  • Page 13 The CA165 cable input pin out is not compatible with the 3093 ISA digital I/O board. If you are upgrading from the 3093 and wish to preserve existing infrastructure wiring, order the CA378 cable. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 14 Port D Output Pin Pairs Pin Pairs 2,20 10,28 3,21 11,29 4,22 12,30 5,23 13,31 6,24 14,32 7,25 15,33 8,26 16,34 9,27 17,35 Ground 18,36,37 + 5 Volts + 12 Volts © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 15 54,73 46,65 3,21 11,29 53,72 45,64 4,22 12,30 52,71 44,63 5,23 13,31 51,70 43,62 6,24 14,32 50,69 42,61 7,25 15,33 49,68 41,60 8,26 16,34 48,67 40,59 9,27 17,35 39,57,58 18,36,37 +12V © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 16 The relay ports return the ones complement of the value that is currently being used to drive the relays. Writing the Outputs The output ports are the only ports that can be written. The relays on a standard DIO-32.PCIe are normally open. To close a relay a one must be written to the appropriate bit.
  • Page 17 The CA378 cable is designed specifically for customers upgrading from a 3093 ISA board to the 8004 PCI board. If you are not upgrading from the 3093 board, use the standard CA165 cable that ships with the 8004 PCI digital I/O board. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 18 Port D Bit Relay Port D Pins 2,20 10,28 3,21 11,29 4,22 12,30 5,23 13,31 6,24 14,32 7,25 15,33 8,26 16,34 9,27 17,35 Ground 18,36,37 + 5 Volts + 12 Volts © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 19: Example Circuits

    In the above circuit diagram, Outputn is one of the two Output Pair Pins from the table labeled Output Ports Pin Assignments. Common is the other pin listed in Output Pair Pins. Since this is an isolated output, the polarity is not important. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 20: Software Installation

    The software is now installed, and you can proceed with the hardware installation. Do not connect the hardware until the software has been successfully installed. To install Sealevel software, you must log in as an administrator or have administrator privileges in Windows.
  • Page 21 9. Using your favorite text editor, edit the /etc/seaio.conf 10. Within the quote marks, insert cardtype=0xYourSeaIOcardType io=0xCardBaseAddress YourSeaIOcardType = Model Number of your SeaIO Card. CardBaseAddress = What base address you have your SeaIO card addressed at. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 22 To set up Linux to automatically load the driver; refer to a Linux manual concerning your specific distribution for help. For additional software support, please call Sealevel Systems’ Technical Support, (864) 843-4343. Our technical support is free and available from 8:00 AM - 5:00 PM Eastern Time, Monday through Friday. For email support contact: support@sealevel.com.
  • Page 23: Appendix A - Handling Instructions

    6. Keep work area free of non-conductive materials such as ordinary plastic assembly aids and Styrofoam. 7. Use field service tools such as cutters, screwdrivers, and vacuum cleaners that are conductive. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 24: Appendix B - Troubleshooting

    5. Use the VCTest to verify the basic I/O functionality of your digital I/O board. The source code is included to simplify application development in the programming language C. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 25 6. VBTest is another utility included with SeaI/O Classic software. The source code is included to aid with Visual Basic application development. 7. SeaIOTST is a command line utility that allows you to test the function calls from the SeaI/O Classic API. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 26 Programmers Interface section. If these steps do not solve your problem, please call Sealevel Systems’ Technical Support, (864) 843-4343. Our technical support is free and available from 8:00 A.M.- 5:00 P.M. Eastern Time Monday through Friday.
  • Page 27: Appendix C - How To Get Assistance

    When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
  • Page 28: Appendix D - Drawing

    Appendix D – Drawing © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 29: Appendix E - Compliance Notices

    Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. © Sealevel Systems, Inc. 8004e Manual | SL9207 12/2022...
  • Page 30: Warranty

    Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn-in and testing.