Removing and replacing an energy pack

Removing and replacing an energy pack
This server supports the installation of a centralized backup power source option to back up write cache content on P-class HPE Smart
Array controllers in case of an unplanned server power outage. Use this procedure to remove and replace either the HPE Smart Storage
battery or the HPE Smart Storage Hybrid Capacitor.
NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy
NOTE:
pack refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors.
Procedure
Procedure
1. Power down the server (Power down the server).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack ( Extend the server from the rack ).
Remove the server from the rack ( Remove the server from the rack ).
4. Remove the access panel ( Remove the access panel ).
5. Do one of the following:
Remove the air baffle ( Removing the air baffle ).
Remove the 4 LFF midplane cage ( Removing and replacing a 4 LFF midplane cage ).
6. Remove the fan cage (Removing and replacing the fan cage ).
7. Disconnect the cable, and then remove the energy pack.
To replace the component, reverse the removal procedure.