Page 1
Codelocks Support KL1200 - Right Hand Programming & Operating Instructions Codes - The Basics The KitLock has four code levels available: 1. Master Code 2. Sub-Master Code 3. User Code 4. Technician Code The KitLock is supplied with two factory set codes: 1.
Page 2
A code cannot be programmed into more than one level Lost Code Procedure Note: The procedure requires the door to be open • Remove the rear-fixing bolt and swing the lock over the edge of the door to reveal the battery compartment https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions...
Page 3
When the battery power is low the Red LED will flash 3 times before the Blue LED flashes to signal acceptance of the code. Batteries should be changed as soon as this happens. The lock will operate for 100 times with low battery. https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions...
Page 4
#Master Code • 65 • New Master Code • New Master Code •• Example: #55443322 • 65 • 12345678 • 12345678 •• Result: Master Code has been changed to 12345678. Note: # prefix not required when in B) Public Use Set or change the USER CODE #Master Code • 60 • User Code •• Example: #55443322 • 60 • 9999 •• Result: New User Code 9999now operative. https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions...
Page 5
Result: Sub-MasterCode has been changed to 10101010. Note: # prefix not required when in B) Public Use Set or Change the USER CODE #Sub-Master Code • 62 • User Code •• Example: #87654321 • 62 • 6666 •• Result: New User Code 6666 now operative. Delete USER CODE #Sub-Master Code • 67 •• Example: #87654321 • 67 •• Result: User Code deleted. https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions...
Page 6
User Code. Please note that the keypad is now inactive when the lever is in the open position 2. Only the Master Code and Sub-Master Code will be retained from Private Use Function Changing from PUBLIC USE to PRIVATE USE #Master Code • 55 •• Example: #55443322 • 55 •• https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1200-right-hand-programming-operating-instructions...
Page 7
Special Note : The number of hours the lock can be set to remain locked is 2, 4, 6, 8, 10 or 12 hours. On the KL1200 Right Hand version keypad this is set as follows: 2h=60, 4h=69, 6h=68, 8h=67, 10h=56 #Master Code • 56 • (Number of hours lock to remain...
Need help?
Do you have a question about the KL1200 and is the answer not in the manual?
Questions and answers