TROUBLESHOOTING

Symptom:
Extractor does not run! No power to the machine!
Problem:
Blown fuse/circuit breaker in the building / room has tripped.
Solution:
Replace fuse with the same rating. Reset circuit breaker. Make sure no other appliances
are connected on the same circuit as the machine. The machine requires a dedicated 15
amp circuit.
Problem:
Frayed cord, damaged plug or loose internal wiring.
Solution:
Have an authorized service technician check cord and replace if necessary. Have an
authorized service technician open switch panel and check for loose wire connection.
Symptom:
Insufficient vacuuming power!
Problem:
Float in the recovery tank is not at the bottom of the unit.
Solution:
Open the screw cap and push the float down..
Problem:
Vacuum hose not connected.
Solution:
Connect hose.
Problem:
Tank cover not properly seated or gasket on dome cover is damaged.
Solution:
Reseat tank cover correctly or replace gasket.
Problem:
Filter in tank cover blocked.
Solution:
Clean filter with water.
Problem:
Drain plug or recovery tank not properly placed.
Solution:
Check drain plug and replace properly.
Problem:
Defective vacuum motor (noisy bearing, carbon brush sparking burn out armature and
worn out carbon brush)
Solution:
Have an authorized service technician replace vacuum motor and motor gasket.
Symptom:
Little or no solution pressure.
Problem:
Pump is off.
Solution:
Turn pump on.
Problem:
Solution line blocked.
Solution:
Flush out solution tank and lines with clean water. Also check quick disconnects for
debris.
Problem:
Solution tank filter / intake clogged.
Solution:
Unclog filter / solution intake.
Problem:
Pump is not working.
Solution:
Have an authorized service technician check and replace pump.
Problem:
Solution tank empty.
Solution:
Refill solution tank.
Problem:
Spray jets at tool clogged.
Solution:
Remove the jet from the end of the hand-tool and press trigger of tool. If the pump
functions clean the jet and/or replace..
Service and repairs should only be performed
by an authorized service center.
Safety, Operation and Maintenance Manual for Spotter; Version 1.2
WARNING
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sparrow and is the answer not in the manual?

Table of Contents