E+E Elektronik EE211 Quick Manual page 2

Humidity and temperature sensor for continuous high humidity
Hide thumbs Also See for EE211:

Advertisement

Modbus Register Map
FLOAT 32 bit (read register):
Function code /
Register address
Register number
[Dec]
1)
30026
0x19
30028
0x1B
30030
0x1D
30032
0x1F
30034
0x21
30036
0x23
30038
0x25
30040
0x27
30042
0x29
INTEGER 16 bit (read register):
Function code /
Register address
Register number
[Dec]
1)
30301
0x12C
30302
0x12D
30303
0x12E
30304
0x12F
30305
0x130
30306
0x131
30307
0x132
30308
0x133
30309
0x134
INTEGER 16 bit (read and write register):
Function code / Register number
[Dec]
1)
60001
60002
INFO (read register):
Function code / Register number
[Dec]
1)
30001
30009
30010
1) Register number starts from 1
2) Register address starts from 0
3) The choice of measurement units (metric or non-metric) must be done in the ordering guide, see EE211 data sheet.
Switching from metric to non-metric or vice versa by using the EE-PCS is not possible.
4) 100 is scale 1:100 (2550 is equivalent to 25.5 °C)
5) If the ID is set via DIP-switch the response will be NAK
6) For Modbus protocol settings please see Application Note Modbus AN0103 (available on www.epluse.com/EE211)
USA
FCC notice:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the installation manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CANADIAN
ICES-003 Issue 5:
CAN ICES-3 B / NMB-3 B
INFORMATION
Langwiesen 7 • A-4209 Engerwitzdorf
Tel: +43 7235 605-0 • Fax: +43 7235 605-8
info@epluse.com • www.epluse.com
LG Linz Fn 165761 t • UID-Nr. ATU44043101
Place of Jurisdiction: A-4020 Linz • DVR0962759
2)
[Hex]
Parameter name
temperature
relative humidity
water vapour partial pressure
dew point temperature
wet bulb temperature
absolute humidity
mixing ratio
specific enthalpy
frost point temperature
[Hex]
Parameter name
2)
temperature
relative humidity
water vapour partial pressure
dew point temperature
wet bulb temperature
absolute humidity
mixing ratio
specific enthalpy
frost point temperature
Register address
[Hex]
2)
0x00
0x01
Register address
[Hex]
2)
0x00
0x01
0x09
+43 7235 605 0 / info@epluse.com
Unit
3)
[°C], [°F]
[%]
[mbar], [psi]
[°C], [°F]
[°C], [°F]
[g/m³], [g/ft³]
[g/kg], [gr/lb]
[kJ/kg], [BTU/lb]
[°C], [°F]
Unit
3)
[°C], [°F]
[%]
[mbar], [psi]
[°C], [°F]
[°C], [°F]
[g/m³], [g/ft³]
[g/kg], [gr/lb]
[kJ/kg], [BTU/lb]
[°C], [°F]
Parameter name
Slave-ID
modbus address
5)
Modbus protocol settings
6)
Parameter name
Serial number (as ASCII)
Firmware version
Sensor name
BA_EE211_QGMS_e // v1.1 // Modification rights reserved // 350182
Scale
4)
100
100
100
100
100
100
100
100
100