Calibration Procedure For Terminal Fm When Using The Operation Panel (Fr-Du08) - Mitsubishi Electric FATEC FR-A800 Manual

Inverter school text, inverter trouble shooting course
Hide thumbs Also See for FATEC FR-A800:
Table of Contents

Advertisement

2
UNDERSTANDING INVERTER SYSTEM
2.5.11 Calibration procedure for terminal FM when using the operation
panel (FR-DU08)
1. Turning ON the power of the inverter
The operation panel is in the monitor mode.
Changing the operation mode
2.
Press
Calibration is also possible in the External operation mode.
Parameter setting mode
3.
Press
Selecting the calibration parameter
4.
Turn
Selecting the parameter
Turn
5.
parameter setting.
The monitored value of the item (initially the output frequency) selected by M300 (Pr.54) FM/CA terminal function
selection will appear.
Pulse output from terminal FM
If the inverter is stopped, press
6.
motor connection is not required.)
Calibration is also possible in a stop status.
Scale adjustment
7.
Turn
Setting completed
Press
8.
to choose the PU operation mode. The [PU] indicator turns ON.
to choose the parameter setting mode. (The parameter number read previously appears.)
until "
" appears. Press
until "
"(M310 (Pr.900) FM/CA terminal calibration) appears. Press
or
to move the meter needle to a desired position.
to enter the setting. The monitored value and "
• Turn
to read another parameter.
• Press
to return to the
• Press
to return to the monitored value of step 5.
2.5 How to use the operation panel FR-DU08
Operation
to display "
".
to start the inverter operation. (To monitor the output frequency,
" are displayed alternately.
display.
"
"
1
2
3
to enable the
4
5
6
7
8
21