Mitsubishi Electric FATEC FR-A800 Manual page 41

Inverter school text, inverter trouble shooting course
Hide thumbs Also See for FATEC FR-A800:
Table of Contents

Advertisement

2
UNDERSTANDING INVERTER SYSTEM
(5) Cursor function
The numeric value of the waveform at the cursor, effective value, maximum value, and minimum
value between any 2 points can be displayed.
A
C
D
E
F
G
Symbol
Name
Vertical/horizontal
A
cursor
B
Cursor bar
C
Setting
D
Horizontal axis
E
Vertical axis
F
A - B
G
Help area
2.6 Inverter setup software
36
Used to specify cursor A and cursor B as the vertical axis or horizontal axis.
Used to specify the position between cursor A and cursor B.
Data type
Used to select the analog CH subject to the cursor measurement.
ON: Moves the cursor so as not to change the value of the vertical scale or horizontal
Follow waveform
scale.
OFF: Moves the cursor so as not to change the position of the graph display area.
A
Shows the time (ms) at cursor point A.
B
Shows the time (ms) at cursor point B.
A - B
Shows the time (ms) between cursor points A and B.
A
Shows the measured value at cursor point A.
B
Shows the measured value at cursor point B.
A - B
Shows the values between cursor points A and B.
Effective value
Calculates and displays the effective value between cursor A and cursor B.
Maximum value
Shows the maximum value between cursor A and cursor B.
Minimum value
Shows the minimum value between cursor A and cursor B.
Shows a description of the currently selected item.
B
Function and description