24/11/2022, 15:52
Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
4
8
16
32
64
128
Parameter 49: Temperature Upper Limit
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor.
Size: 2 Byte, Default Value: 280
Setting
-400 - 1000
Parameter 50: Temperature Lower Limit
Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor.
Size: 2 Byte, Default Value: 0
Setting
-400 - 1000
Parameter 51: Temperature Recover Limit
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
Description
Disable
Temperature upper level
Humidity upper level
Lux upper level
UV upper level
Temperature lower level
Humidity lower level
Lux lower level
UV lower level
Description
Set upper limit level for temperature
Description
Set lower limit level for temperature