Download Print this page
Aeotec Z-Wave Multisensor DSB05-ZWEU Instruction Manual

Aeotec Z-Wave Multisensor DSB05-ZWEU Instruction Manual

Advertisement

Available languages
  • EN

Available languages

Quick Links

Z-Wave Multisensor
Art.no 36-5746
Model DSB05-ZWEU
Please read the entire instruction manual before using the product
and then save it for future reference. We reserve the right for any
errors in text or images and any necessary changes made to
technical data. In the event of technical problems or other queries,
please contact our Customer Services.
Things to consider:
Other wireless equipment using the same frequency band can
reduce the transmission range.
The range of all wireless equipment depends on the type of
obstacles located between the transmitter and the receiver
(e.g. a concrete wall will interfere with the signal more than
a plasterboard wall).
If you experience problems, try the following:
Turn off any other existing wireless equipment to check whether
this is the cause of the problem.
Reposition the wireless equipment, shorten the distance
between the transmitter and the receiver or reduce the number
of obstacles (walls, furniture, etc.) between them.
Safety
Never subject the sensor to high temperature, dust, heavy
vibration, impacts, humidity or moisture.
Never attempt to dismantle or modify the sensor as it contains
no user-serviceable parts.
Product description
Z-Wave DSB05-ZWEU 4-in-1 Multisensor
Battery powered, wireless sensor for use with Zipabox Duo and
other Z-wave-system products, regardless of make. Motion sensor,
temperature sensor, humidity sensor and light sensor.
PIR sensor/motion sensor
The PIR sensor can be used to actuate the majority of the devices
in your Z-wave system, such as activate a burglar alarm, turn a light
on or execute other commands.
Temperature and humidity sensor
By monitoring the temperature and humidity of a space it is possible
to programme the Z-Wave system to remotely control devices to
create the perfect atmosphere.
Light sensor
By programming in commands or scenarios, the light sensor can be
used to control devices depending on the level of light at the place
where the sensor is placed.
The sensor comes with mounting plates for attaching it to the wall
or ceiling. It can be used indoors or outdoors and can send signals
to up to six other Z-Wave devices.
For more information please
visit www.aeotec.com
for a complete
instruction manual.
GREAT BRITAIN • customer service tel: 0845 300 9799 e-mail: customerservice@clasohlson.co.uk internet: www.clasohlson.com/uk
1
2
3
4
5
6
7
8
1. Motion sensor
2. LED indicator
3. [ Sensitivity ] Sensitivity dial
4. Temperature and Humidity sensor
5. Z-Wave Button – Button for pairing to Z-Wave system
6. USB port
7. Mounting arm (ball-joint mount for wall or ceiling)
8. Mounting plate (fixed mount for wall or ceiling)
USB or battery power
Batteries should be used for periodic use.
The USB port should be used for continuous use.
Batteries
1. Twist the battery cover to
the unlocked position and
remove it.
2. Insert 4 × AAA/LR03 batteries.
Note the polarity markings in
the battery holder to ensure
correct battery insertion.
3. Refit the battery cover and twist it
to the locked position.
4. If your Z-Wave system can display the battery level of
the multisensor, the battery status will be displayed once
the multisensor has been paired to the system.
5. If your system does not have a method of displaying the battery
level, it is recommended that the batteries are checked regularly.
USB port
1. Twist the battery cover to
the unlocked position and
remove it.
2. Connect the included USB
lead to the charging port (6)
on the multisensor and to
a computer or other USB
charger.
3. Refit the battery cover
and twist it to the locked
position.
Motion sensor effective range
When mounted on the ceiling
Ceiling
Floor/Ground
When mounted on a wall
Floor/Ground
Installation/Pairing
1. Set your Z-Wave control device to learning mode.
2. Push the Z-Wave button (5) on the sensor to connect it to your
existing Z-Wave network.
3. The Z-Wave button can also be used to test whether
the connection/pairing process was successful. If the LED
indicator (2) flashes when the Z-Wave button is pressed,
the sensor is not paired. If the LED indicator shines steadily for
a few seconds when the Z-Wave button is pressed, the sensor
is paired.
Mounting
Fixed mounting plate
1. Mount the fixed mounting plate
(8) to the ceiling or wall using
suitable screws and wall plugs.
Make sure that there are no
hidden electrical cables or water
pipes in the wall/ceiling which
could be damaged by drilling
the mounting holes.
2. Hook the sensor onto
the mounting plate.
Mounting arm
1. Mount the mounting arm (7) to the ceiling or wall using suitable
screws and wall plugs. Make sure that there are no hidden
electrical cables or water pipes in the wall/ceiling which could be
damaged by drilling the mounting holes.
2. Remove the screw
3. Screw the fixed mounting
from the centre (ball) of
plate to the mounting arm.
the mounting arm.
4. Hook the sensor onto
the mounting plate.
5. The mounting arm can be
locked in various angles
by turning the Friction
Lock clockwise, adjusting
the angle, and then
turning the Friction Lock
anticlockwise.
Care and maintenance
Clean the product using a lightly moistened cloth. Use only mild
cleaning agents, never solvents or corrosive chemicals.
Remove the batteries and disconnect the USB cable from
the sensor if the product is not to be used for an extended
period.
Disposal
This product should be disposed of in accordance with local
regulations. If you are unsure how to proceed, contact your
local council.

Advertisement

loading

Summary of Contents for Aeotec Z-Wave Multisensor DSB05-ZWEU

  • Page 1 If the LED indicator shines steadily for to up to six other Z-Wave devices. a few seconds when the Z-Wave button is pressed, the sensor is paired. For more information please visit www.aeotec.com for a complete instruction manual. GREAT BRITAIN • customer service tel: 0845 300 9799 e-mail: customerservice@clasohlson.co.uk internet: www.clasohlson.com/uk...
  • Page 2: Installation

    3. Du kan kontrollera om anslutningen lyckades genom att trycka symbolen. kontakta din kommun. på anslutningsknappen. Om LED-indikatorn (2) blinkar är Besök gärna www.aeotec.com för en fullständig bruksanvisning. sensorn inte ansluten. Om LED-indikatorn lyser med fast sken i några sekunder är sensorn ansluten. SVERIGE • kundtjänst tel. 0247/445 00 fax 0247/445 09 e-post kundservice@clasohlson.se...
  • Page 3 Hvis LED-indikatoren (2) blinker er sensoren ikke i Z-wave-systemet ditt. koblet til. Hvis LED-indikatoren lyser i noe sekunder er sensoren koblet til. Komplett bruksanvisning er å finne på www.aeotec.com. NORGE • kundesenter tel. 23 21 40 00 fax 23 21 40 80 e-post kundesenter@clasohlson.no internett www.clasohlson.no...
  • Page 4 Z-wave-järjestelmässä olevaan laitteeseen. 3. Voit tarkistaa liitännän onnistumisen painamalla liitäntäpainiketta. takaisin paikalleen lukitse Jos LED-merkkivalo (2) vilkkuu, anturia ei ole liitetty. Jos LED- se kiertämällä sitä nuolen Osoitteessa www.aeotec.com voit tarkastella käyttöohjetta merkkivalo palaa vilkkumatta muutaman sekunnin ajan, anturi osoittamaan suuntaan. kokonaisuudessaan. on liitetty.
  • Page 5: Montage

    Wenn die LED (2) blinkt ist der Sensor nicht verbunden. draußen. Der Sensor kann Signale an bis zu 6 versch. Geräte im Wenn die LED für ein paar Sekunden leuchtet ist der Sensor Z-Wave-System schicken. verbunden. Eine ausführliche Bedienungsanleitung ist auf www.aeotec.com zu finden. DEUTSCHLAND • Kundenservice Unsere Homepage www.clasohlson.de besuchen und auf Kundenservice klicken.
  • Page 6: Declaration Of Conformity

    Declaration of Conformity Hereby, Clas Ohlson AB declares that following product(s): Multisensor 36-5746 DSB05-ZWEU is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Article 3.1a (Safety): EN 62479 Article 3.1b (EMC): EN 301 489-1 EN 301 489-3 Article 3.2 (Radio): EN 300 220-1 EN 300 220-2...