Aeotec
Indoor Siren 6
SKU: AEOEZW164
Quickstart
This is a secure Sound Switch for Europe. To run this device please connect it to your mains power supply. 1. Set your Z-Wave Controller into its
Device
mode in order to add siren into your Z-Wave system. Refer to the Controller
2. Power on siren via the provided power adapter; its LED will be breathing white light all the time.
3. Click siren Action Button once, it will quickly flash white light for 30 seconds until siren is added into the network. It will become constantly bright white
light after being assigned a NodeID.
4. If your Z-Wave Controller supports S2 encryption, enter the first 5 digits of DSK into your Controller
on Siren
s housing.
5. If Adding fails, it will slowly flash white light 3 times and then become breathing white light; repeat steps 1 to 4. Contact us for further support if needed.
6. If Adding succeeds, it will quickly flash white light 3 times and then become off. Now, Siren is a part of your Z-Wave home control system. You can
configure it and its automation via your Z-Wave system; please refer to your software
Note:If Action Button is clicked again during the Learn Mode, the Learn Mode will exit. At the same time, Indicator Light will extinguish immediately, and
then become breathing white light.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-
Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product Description
- S2 Security.- Not only a siren, but also can be used as a doorbell via setting.- Can be wireless controlled by more Button, up to 3.- Longer Button control
distance, up to 120m.- Built-in multiple tones, up to 30.- Built-in multiple adjustable Light Effect.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To complete the reset process manually, press and hold the Action Button for at least 20s. The LED indicator will quickly flash white light 3 times and then become
breathing white light, which indicates the reset operation is successful.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the
assembly of the product, the voltage network has to be switched off and ensured against re-switching.
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164
s manual if you are unsure of how to perform this step.
s interface if/when requested. The DSK is printed
s user guide for precise instructions.
A dd
1/10

Advertisement

Table of Contents
loading

Summary of Contents for Aeotec Indoor Siren 6

  • Page 1 Aeotec Indoor Siren 6 SKU: AEOEZW164 Quickstart This is a secure Sound Switch for Europe. To run this device please connect it to your mains power supply. 1. Set your Z-Wave Controller into its A dd ‘ Device mode in order to add siren into your Z-Wave system. Refer to the Controller s manual if you are unsure of how to perform this step.
  • Page 2: Installation

    29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Installation Install Mounting plate in the location of your choice.   1. Affix Siren 6 Wall Mount Plate in any desired location near an outlet. a. Use 3x 20mm screws or double-sided tape. b. Lock the Siren 6 into place where the mount is installed Inclusion/Exclusion On factory default the device does not belong to any Z-Wave network.
  • Page 3: Quick Troubleshooting

    29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 ’ Quick trouble shooting Here are a few hints for network installation if things dont work as expected. 1. Make sure a device is in factory reset state before including. In doubt exclude before include. 2. If inclusion still fails, check if both devices use the same frequency. 3.
  • Page 4 29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Setting Description 16777216 - 2147483647 Configure the Light Effect and Tone Effect for Endpoint 2(Tampering). Parameter 3: Configure the Light Effect and Tone Effect for Endpoint 3(Doorbell 1). Please refer to the Product Manual for more details. Size: 4 Byte, Default Value: 33554433 Setting Description 16777216 - 2147483647...
  • Page 5 29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Setting Description 0 - 2147483647 The Light Effect is displayed cyclically, and the maximum display duration is equal to the total duration of the tone playback. In other words, the Light Effect will be displayed in a loop until stop playing tone. Parameter 19: Configure #4 Light Effect.
  • Page 6 29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Parameter 34: Configure how to send Basic Set to nodes in Group 4. Size: 1 Byte, Default Value: 3 Setting Description Dont send Basic Set. When Endpoint 3 starts playing tone, send Basic Set 0xFF. When Endpoint 3 stops playing tone, dont send Basic Set.
  • Page 7 29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Setting Description Dont send Basic Set. When Endpoint 7 starts playing tone, send Basic Set 0xFF. When Endpoint 7 stops playing tone, dont send Basic Set. When Endpoint 7 starts playing tone, send Basic Set 0x00. When Endpoint 7 stops playing tone, dont send Basic Set.
  • Page 8: Technical Data

    29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Parameter 51: Report which Buttons had been paired (Read Only) Once Unpairing or Pairing Button Mode finishes, node will automatically send this configuration report via Lifeline to inform which Buttons had been paired. This parameter does not restore to the default value when Siren is removed from the network or reset the factory settings. Size: 1 Byte, Default Value: 0 Setting Description...
  • Page 9: Supported Command Classes

    29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Dimensions 70x70x40 mm Weight 200 gr Hardware Platform ZM5101 1220000016224 IP Class IP 20 Voltage Device Type Sound Switch Network Operation Always On Slave Z-Wave Version 6.71.03 Certification ID ZC10-19046420 Z-Wave Product Id 0x0371.0x0003.0x00A4 Supported Notification Types Home SecurityPower ManagementSiren Color White Sensors...
  • Page 10 29-9-2020 manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW164 Inclusion — is the process of adding new Z-Wave devices into a network. Exclusion — is the process of removing Z-Wave devices from the network. Association — is a control relationship between a controlling device and a controlled device. Wakeup Notification —...

This manual is also suitable for:

Aeoezw164

Table of Contents