Mounting The Device; Mounting The Device On A Din Rail - Siemens SIMATIC NET RUGGEDCOM RS400F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS400F:
Table of Contents

Advertisement

2.3

Mounting the Device

The RUGGEDCOM RS400F is designed for maximum mounting and display flexibility.
It can be equipped with connectors that allow it to be installed in a rack, on a DIN
rail, or directly on a panel.
Heat generated by the device is channeled outwards from the enclosure. As such, it
is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the
device to allow for some convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Note
For detailed dimensions of the device with either rack, DIN rail or panel hardware
installed, refer to
2.3.1

Mounting the Device on a DIN Rail

The RUGGEDCOM RS400F can be ordered with panel/DIN rail adapters preinstalled on
each side of the chassis. Use the adapters to mount the device to a standard 35 mm
(1.4 in) IEC/EN 60715 or TS35 DIN rail.
Mounting the Device
To mount the device to a DIN rail, do the following:
1.
RUGGEDCOM RS400F
Installation Manual, 11/2022, C79000-G8976-1341-06
NOTICE
"Dimension Drawings" (Page
Hook the top teeth of the adapters onto the DIN rail.
1
2
Panel/DIN Rail Adapter
1
DIN Rail
2
2
Installing the Device
2.3 Mounting the Device
29).
1
3
2
9