Reboot - D-Link DGS-1250 Series Reference Manual

Cli gigabit ethernet smart managed switch
Hide thumbs Also See for DGS-1250 Series:
Table of Contents

Advertisement

DGS-1250 Series Gigabit Ethernet Smart Managed Switch CLI Reference Guide
Example
This example shows how to ping the host with IP address 172.50.71.123.
Switch#ping 172.50.71.123 count 5
Reply from 172.50.71.123, time<10ms
Reply from 172.50.71.123, time<10ms
Reply from 172.50.71.123, time<10ms
Reply from 172.50.71.123, time<10ms
Reply from 172.50.71.123, time<10ms
Ping Statistics for 172.50.71.123
Packets: Sent =5, Received =5, Lost =0
Switch#
This example shows how to ping the host with IPv6 address 2001:238:f8a:77:7c10:41c0:6ddd:ecab.
Switch#ping 2001:238:f8a:77:7c10:41c0:6ddd:ecab count 3
Reply from 2001:238:f8a:77:7c10:41c0:6ddd:ecab, bytes=100, time<10 ms
Reply from 2001:238:f8a:77:7c10:41c0:6ddd:ecab, bytes=100, time<10 ms
Reply from 2001:238:f8a:77:7c10:41c0:6ddd:ecab, bytes=100, time<10 ms
Ping Statistics for 2001:238:f8a:77:7c10:41c0:6ddd:ecab
Packets: Sent =3, Received =3, Lost =0
Switch#
2-13

reboot

This command is used to reboot the Switch.
reboot [force_agree]
Parameters
force_agree
Default
None.
Command Mode
EXEC Mode.
Usage Guideline
This command is used to reboot the Switch.
(Optional) Specifies to restart the Switch without confirmation.