WARNING
Do not incinerate a battery or store at high temperatures as it will explode.

Conditioning a battery

Batteries should be conditioned regularly to maintain their useful life. Condition a battery every
six months, when its run time becomes noticeably shorter, or when the message 'Condition
Battery x' appears on the screen. Conditioning a battery is best done on an external charger.
Please, refer to instructions provided with the charger.
If you do not have an external charger, see section
battery".

Symbols and abbreviations

Equipment safety symbols

-
Attention, consult accompanying documents.
-
On the modules or frames indicates that modules with identical
measurements should not be used in the same monitor. If such modules
have been inserted, remove the module that has been most recently
connected. You can also remove both modules and re-connect the new
module after five seconds.
-
On the E-PSM(P)W module indicates that protection against cardiac
defibrillator discharge is due in part to the accessories for pulse oximetry
(SpO
), temperature (T) and invasive pressure (P) measurement.
2
-
On the N-FC(REC) module indicates that airway gases should be calibrated
every six months in normal use and every two months in continuous use.
-
On top of the monitor beside the battery cover: Use manufacturer
recommended batteries only. Follow the regional regulations for disposal.
-
On the rear panel this symbol indicates the following warnings and
cautions:
* Electric shock hazard. Do not open the cover or the back. Refer servicing
to qualified service personnel.
* For continued protection against fire hazard, replace the fuse only with
one of the same type and rating.
* Disconnect from the power supply before servicing.
* Do not touch the monitor during defibrillation.
* Do not use the monitor without manufacturer approved mounting
attached.
* Lithium battery on the CPU board: follow the regional regulations for
disposal.
* Use manufacturer recommended batteries only.
Type BF (IEC 60601-1) protection against electrical shock.
Type BF (IEC 60601-1) defibrillator-proof protection against electric shock.
Type CF (IEC 60601-1) protection against electric shock.