Sensor-to-cloud device for seamless cloud integration of industrial sensors. (23 pages)
Summary of Contents for Hydac CMP 43x0-7/-T013 Series
Page 1
CMP 43x0-7-... /-T013 ConditionMonitoring Package Installation and Maintenance Instructions English (translation of original instructions) Document No. : 4631954 Follow these instructions for proper and safe use. Keep for future reference.
Page 2
Court of Registration: Saarbrücken, HRB 17216 Executive directors: Mathias Dieter, Dipl.Kfm. Wolfgang Haering CE - Documentation Representative Günter Harge c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Germany Telephone: +49 6897 509 1511 Fax: +49 6897 509 1394 E-mail: guenter.harge@hydac.com UKCA –...
HYDAC FILTER SYSTEMS GMBH Table of Contents Table of Contents General ........................ 5 Target group of the manual ................ 5 Illustrations in the manual................ 6 1.2.1 Illustration on the title page .............. 6 1.2.2 Representation of requirements............ 7 1.2.3 Representation of procedural instructions ......... 7 1.2.4 Representation of intermediate results/results........ 8...
Page 4
Table of Contents HYDAC FILTER SYSTEMS GMBH Making the electrical connections .............. 36 4.2.1 Connecting the electric motor, 1-phase ........... 36 4.2.2 Connecting the electric motor, 3-phase ........... 37 Commissioning ..................... 38 Operation ........................ 39 Evaluating/reading measurement reports/values with FluMoS .... 39 Rectifying malfunctions................... 40 Performing Maintenance .................. 42 Maintenance table .................. 43...
HYDAC FILTER SYSTEMS GMBH General | 1 1 General Before you use this product for the first time, read this manual at least up to the chapter "Operation". If you would like to carry out maintenance or troubleshooting, you can find the procedure in the respective chapters.
1 | General HYDAC FILTER SYSTEMS GMBH 1.2 Illustrations in the manual You will find illustrations in this manual. You can find details regarding these in the following chapters. 1.2.1 Illustration on the title page You will find the following information on the title page of this...
HYDAC FILTER SYSTEMS GMBH General | 1 The document no. with the index (4) is meant for identifying and reordering the manual. The index is incremented every time the manual is revised or changed. The manual contains a table of contents, a list of tables and figures, an index and a glossary.
1 | General HYDAC FILTER SYSTEMS GMBH – Rinse the product. 1.2.4 Representation of intermediate results/results In the case of some activities, it is necessary to carry out work steps with intermediate results and end results. Intermediate results are the consequence of activities; they are marked with an indented arrow.
HYDAC FILTER SYSTEMS GMBH General | 1 1.2.5 Supplementary symbols You will find the following symbols in the manual as additional details: u ## Cross reference to a page / a chapter / a section or another document. Glossary Terms in grey are explained in detail in the glossary, a chapter at the end of the manual.
1 | General HYDAC FILTER SYSTEMS GMBH 1.2.7 Signal words and their meaning in the general safety information In these instructions you will find the following signal words: DANGER DANGER – The signal word indicates a hazardous situation with a high level of risk, which, if not avoided, will result lethal or serious injury.
HYDAC FILTER SYSTEMS GMBH General | 1 1.3 Exclusion of liability / warranty For the warranty provided by us, please refer to our terms of delivery. They are made available to you at the conclusion of the contract at the latest. In addition, you will find these under www.hydac.com ->...
2 | Safety HYDAC FILTER SYSTEMS GMBH 2 Safety The product is designed as safe. In spite of that, there is danger in some actions that can only be avoided by using the right procedures. These correct procedures and points, which must be followed, are described in this manual.
Page 13
HYDAC FILTER SYSTEMS GMBH Safety | 2 – To provide the necessary protective equipment to the personnel Personnel who work with the product must be aware of the dangers involved in handling it, must be over 14 years of age and must be without any physical impediments in regard to the industrial environment.
2 | Safety HYDAC FILTER SYSTEMS GMBH Activity Personnel Knowledge Disposal Specialist Knowledge of environ- personnel - mentally friendly General disposal of materials and matter is required. Knowledge of decon- tamination of contami- nants is required. Knowledge of recycling is required.
HYDAC FILTER SYSTEMS GMBH Safety | 2 2.2 Hazard symbols / pictograms The following are the safety symbols / pictograms in this manual. They indicate specific dangers to persons, property or to the surroundings. Observe these safety symbols / picto- grams and act with particular caution in such cases.
Page 16
2 | Safety HYDAC FILTER SYSTEMS GMBH Used GHS symbols These symbols can be found for all safety and warning instruc- tions in this manual which indicate particular dangers to persons, property or the environment. Hazardous to the environment Others symbols used...
HYDAC FILTER SYSTEMS GMBH Safety | 2 These persons have specific specialist training and several years of work experience. They are able to assess and perform the work assigned to them and they are also able to detect potential dangers.
Page 18
2 | Safety HYDAC FILTER SYSTEMS GMBH Environmentally tip Open ports Oil leaking out from open ports u Soak up the leaking oil with an absorbent cloth and dispose of it in an environmentally friendly way. Life phase - Transport / Storage...
Page 19
HYDAC FILTER SYSTEMS GMBH Safety | 2 DANGER Electric voltage warning Danger of fatal injury u In case of any damage to the insulation, switch off the supply voltage immediately and arrange for repairs to be carried out. u Before carrying out any work on the electrical system and before any maintenance, cleaning or repair work, disconnect the supply line or pull out the power plug.
2 | Safety HYDAC FILTER SYSTEMS GMBH 2.4 Observing regulatory information Observe the following regulatory information and directives: – Legal and local regulations for accident prevention – Legal and local regulations for environmental protection and environmental requirements – Country-specific regulations, organization-specific regula- tions –...
HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 3 3 Product and technical specifications The ConditionMonitoring Package CMP is used to continu- ously monitor fluid power systems for solid and/or liquid contaminants. The CMP is equipped with a gear pump which supplies the oil to be analyzed to the MetallicContamination Sensor MCS, in...
3 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH 3.1 Technical data If you are aware of the technical data of the product, you will be able to use it optimally. This chapter provides the technical data of the product:...
HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 3 Ambient and storage conditions Permissible ambient -20 … 40 °C / temperature range -4 … 104 °F Permissible storage -40 … 80 °C / temperature range -40 … 176 °F Permissable relative ≤ 90 %, non-condensing humidity Air conditions Clean, salt-free air, not near oxidizing...
– Check the packaging and the product for damage. Report any damage in transit to the forwarding agent or the HYDAC department in charge. – Check the scope of delivery for completeness. The following items are included in the scope of delivery: Qty.
HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 3 3.3 Intended Use Use the product only for the application described below. The ConditionMonitoring Package CMP is used for continuous monitoring of fluid contamination (solids and fluid contami- nants) in hydraulic systems.
3.4 Improper Use or Use Deviating from Intended Use Any other use or extended use shall not be considered intended use. HYDAC FILTER SYSTEMS GmbH will assume no liability for any damage resulting from such use. This risk is borne solely by the owner.
3.5 Decoding the type label Details for identifying the product are found on the name plates on the product as well as their components. Always mention the part no. and the serial no. when contacting HYDAC. Fig. 2: Decoding the name plate Item Description (1) Type label for ConditionMonitoring Package...
Page 28
3 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH Power Power consumption Max. Flow rate Flow rate Max. Inlet Operating pressure, maximum pressure Weight Weight when empty Sensor voltage Connected load of sensor 28 / 60 MoWa CMP43x0-7 T013 4631954 en-us print...
HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 3 3.5.1 Model code The ConditionMonitoring Package is defined by the following model code: CMP 100 0 – 4 – 1 - W/N/X60/O60 – AS11 /-000 CMP = ConditionMonitoring Package ContaminationSensor 121 = CS1000 -> ISO / SAE without display 122 = CS1000 ->...
3 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH 3.6 Dimensions The CMP has the following dimensions: Fig. 4: Dimensions 1 of 2 (all specifications are in mm) 30 / 60 MoWa CMP43x0-7 T013 4631954 en-us print...
HYDAC FILTER SYSTEMS GMBH Assembly, installation and commissioning | 4 4 Assembly, installation and commissioning An optimally assembled and installed product ensures a safe and continuous operation. Fasten the CMP using the four bore holes Ø 10 mm to a wall. The dimensions to drilling template, see Dimensions [} 30].
4 | Assembly, installation and commissioning HYDAC FILTER SYSTEMS GMBH – Flow – Kinematic viscosity – Pipe dimensions – Fluid density The pressure loss can be estimated as follows for mineral oil- based hydraulic oils: Fig. 8: Pressure loss formula Δp Pressure differential...
HYDAC FILTER SYSTEMS GMBH Assembly, installation and commissioning | 4 4.1.2 Connecting the inlet IN Make the suction-side connection IN with a flexible hose that is resistant to negative pressure or with pipelines. The nominal size of the hose or pipeline should correspond with the cross section of the connection.
4 | Assembly, installation and commissioning HYDAC FILTER SYSTEMS GMBH 4.2 Making the electrical connections Check the connection voltage and the frequency of the electric motor and balance it with the available mains supply. You will find the electric data on the name plate of the electric motor.
HYDAC FILTER SYSTEMS GMBH Assembly, installation and commissioning | 4 4.2.2 Connecting the electric motor, 3-phase Connect the supply voltage in the terminal box of the electric motor. Connecting terminals: L1, L2, L3, (N), PE. Fig. 9: Star delta connection Star (Y) connection Delta connection Checking the direction of rotation.
4 | Assembly, installation and commissioning HYDAC FILTER SYSTEMS GMBH 4.3 Commissioning ü The CMP is connected hydraulically and electrically. 1. Switch on the hydraulic system 2. Open the existing shut-off devices upstream or down- stream the CMP. 3. Check for leaks. Eliminate leakages immediately.
5.1 Evaluating/reading measurement reports/values with FluMoS The FluidMonitoring Software FluMoS is used to read and analyze measurement reports / measured values from the HYDAC sensors / interfaces or devices. FluMoS light is available for download on the homepage www.hydac.com. – Free download –...
6 | Rectifying malfunctions HYDAC FILTER SYSTEMS GMBH 6 Rectifying malfunctions The following errors could occur when handling or operating the ConditionMonitoring Package CMP: Error Cause(s) Rectification No function. No electric Check the feed tension. line, fuse and The motor pump the switch.
HYDAC FILTER SYSTEMS GMBH Rectifying malfunctions | 6 Error Cause(s) Rectification The transport Remove the seals have not transport seals. been removed. The transport seals are the yellow plastic parts. Tab. 8: Error/cause/rectification MoWa CMP43x0-7 T013 4631954 en-us print 41 / 60...
7 | Performing Maintenance HYDAC FILTER SYSTEMS GMBH 7 Performing Maintenance For a long, trouble-free service life of the product, regular maintenance activities are required. This chapter contains the description of the required mainte- nance activities and the qualifications of the staff needed to carry out these tasks.
HYDAC FILTER SYSTEMS GMBH Performing Maintenance | 7 7.1 Maintenance table Additional information Visual check for leaks Visual check of electric equipment 1 - Operating personnel 7.2 Visual check for leaks With a visual check, check the hydraulic connections and components for leaks.
8 | Decommissioning / Disposal HYDAC FILTER SYSTEMS GMBH 8 Decommissioning / Disposal In the following chapters, you will be provided with information regarding temporary shutdown/final decommissioning and disposal of the product. 8.1 Temporary shutdown If the product is being temporarily shut down, the following...
Hotline, product support, Customer Service, Branches, service partners for maintenance, repair and spare parts can be found, always updated, on our homepage www.hydac.com. HYDAC SYSTEMS & SERVICES GMBH Friedrichsthaler Str. 15, Werk 13 66450 Neunkirchen - Heinitz Germany...
A | Appendix HYDAC FILTER SYSTEMS GMBH A.2 Finding spare parts / accessories Use only original spare parts for a long and defect-free life cycle of the product. When ordering spare parts and acces- sories make sure to always indicate the exact model code and the serial number.
HYDAC FILTER SYSTEMS GMBH Appendix | A A.2.1 Finding accessories The following accessories are available for the ConditionMonitoring Package. Connection cable, 5-pin Screwed connection bushing, , -, ZBE00 Socket M12x1, 5-pole, A-coded Description Part no. Screwed connection bushing, ZBE00, Color: -, -...
Page 48
A | Appendix HYDAC FILTER SYSTEMS GMBH Description Part no. Connecting line, L: 5 m, ZBE30-05 6040852 Line sheath: -, color: black, - Connecting line, L: 20 m, ZBE30-20 3761071 Line sheath: -, color: black, - Connecting line, L: 10 m, ZBE30-10 3534972 Line sheath: -, color: black, - Connecting line, L: 30 m, ZBE30-30 3656854 Line sheath: -, color: black, -...
Page 49
HYDAC FILTER SYSTEMS GMBH Appendix | A Single-ended cordset , shielded, ZBE47S M12x1 Socket, 5 -pole, even A-coded <-> Open cable Description Part no. Single-ended cordset, L = 5 m, 3527626 Line sheath: - , Color: black, - ZBE47S-05 Single-ended cordset, L = 10 m, 3527627 Line sheath: - , Color: black, - ZBE47S-10 Single-ended cordset, L = 15 m,...
Page 50
A | Appendix HYDAC FILTER SYSTEMS GMBH Single-ended cordset, shielded, ZBE42S M12x1 Socket, 8 -pin, even A-coded <-> Open cable Designation Part no. Single-ended cordset, L = 2 m, ZBE42S-02 3281220 black, -, - Single-ended cordset, L = 5 m, ZBE42S-05 3281239 black, -, - Single-ended cordset, L = 10 m, ZBE42S-10...
Page 51
HYDAC FILTER SYSTEMS GMBH Table of Illustrations Table of Illustrations Overview / labeling of the title page ............Fig. 1 Decoding the name plate ................. Fig. 2 Model Code ....................Fig. 3 Dimensions 1 of 2 (all specifications are in mm) ........
Page 52
List of Tables HYDAC FILTER SYSTEMS GMBH List of Tables Tab. 1 Target groups ................... Tab. 2 Target group / Required personnel qualification ........Tab. 3 Technical data – Hydraulic data ............... Tab. 4 Technical data – Electrical data..............Tab. 5 Technical data –...
HYDAC FILTER SYSTEMS GMBH Glossary Glossary FluMoS light and parameterize up to 16 sensors via LAN/W-LAN or Bluetooth, depending on your terminal device. General Terms and Conditions The General Terms and Conditions are available at our home page www.hydac.com ⇨ General Terms and Conditions.
Page 54
Glossary HYDAC FILTER SYSTEMS GMBH tivity, the saturation level and the temperature. These measured values are available as sequential analogue signals and/or switching signals at the electrical outlet of the HYDACLAB® (for example, warning, alarms). The measured values can be depicted and...
Need help?
Do you have a question about the CMP 43x0-7/-T013 Series and is the answer not in the manual?
Questions and answers