HYDAC Filter Systems GmbH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the express written consent of HYDAC Filter Systems. Contraventions are liable to compensation. Exclusion of Liability We have made every endeavor to ensure the accuracy of the contents of this document.
FAM Versions (without heater) ................19 Performance ......................20 System components ..................... 21 Suitable Fluids ......................22 Hydraulic plan (without heater)................23 Dimensions ......................24 Stationary version (FAM70 with OLF without heater) ........... 24 HYDAC Filter Systems GmbH Page BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 4
Manual Menu 2 (only with heater option) ............43 Performing Maintenance..................44 Troubleshooting .....................45 Vacuum chamber overfilled ..................48 Level switch 01/02(02/03)..................49 V-pump fill level min/max ..................50 Change fluid filter....................51 Float switch......................52 HYDAC Filter Systems GmbH Page BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 5
Spare Parts......................61 Storing the FAM/Taking it out of Operation ............62 Disposing of the FAM.....................62 Type label ......................62 Model Code ......................63 EU declaration of conformity (only for mobile version) ........64 HYDAC Filter Systems GmbH Page BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
If you discover errors while reading the documentation or have additional comments or suggestions, contact us at: HYDAC Filter Systems GmbH Technische Dokumentation Postfach 12 51 66273 Sulzbach / Saar Germany We look forward to receiving your input.
After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician. Please notify us immediately of any modifications made to the product whether by you or a third party.
The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index is incremented every time the manual is revised or changed. HYDAC Filter Systems GmbH Page BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
• Modifications to the FluidAqua Mobil made by the user or purchaser • Improper monitoring of unit components that are subject to wear and tear • improperly performed repair work HYDAC Filter Systems GmbH Page BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Leaks of dangerous materials must be properly collected and disposed of so as not to harm any persons or the environment. The corresponding statutory regulations are to be followed. HYDAC Filter Systems GmbH Page 10 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
(e.g. warning sign or padlock on the main switch). When the product is supplied in partial consignments, the safety devices are to be applied by the operator as specified by law/pertinent regulations. HYDAC Filter Systems GmbH Page 11 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
WARNING Hydraulic systems are under pressure Bodily injury ► The hydraulic system must be depressurized before performing any work on the hydraulic system. HYDAC Filter Systems GmbH Page 12 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Do not put the FAM into operation unless all the safety devices function properly. The unit is to be checked once a day for visible external damage and for the proper functioning of the safety devices. HYDAC Filter Systems GmbH Page 13 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Do not make any modifications (design modifications, extensions) to the FluidAqua Mobil without the prior consent of the manufacturer. Any conversion modifications require written permission from HYDAC Filter Systems GmbH. Immediately replace any machine components which are not in perfect condition.
When receiving and unpacking the unit check it for damage in transit. Dispose of the packaging material as appropriate for your area. HYDAC Filter Systems GmbH Page 15 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Once the FAM is in its new position, actuate the hand brake on the steering rollers. Fork lift Use the lift eyes when transporting the unit with a forklift. HYDAC Filter Systems GmbH Page 16 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
For transport by rail or truck, supports must be placed under the mobile FAM so that the rollers are subjected to no load pressure. The FAM is to be secured with suitable belts. HYDAC Filter Systems GmbH Page 17 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
In addition to the stationary version, the mobile FAM has: 2 casters, 2 bock rolls Suction hose, L= 5 m Return hose , L= 5 m Connection cable 10m HYDAC Filter Systems GmbH Page 19 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
FAM-50 ≈ 2.2 l/h FAM-70 ≈ 2.6 l/h The dewatering speed is dependent on: Dewatering rate Water content Fluid temperature Detergent additives Volumetric flow of the FAM HYDAC Filter Systems GmbH Page 20 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Vegetable oils (HETG, HTG) • Hydraulic and lubrication oils which require or are compatible with Viton seals. FAM-xx-X-x-x/xxxx-xxx-xx-D-x-x HFD fluids (not for pure phosphate esters which require EPDM seals). HYDAC Filter Systems GmbH Page 22 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
FAM 15/30/50/70 Dimensions Dimensions Stationary version (FAM70 with OLF without heater) 1787 Mobile version (FAM70 with OLF without heater) 1787 HYDAC Filter Systems GmbH Page 24 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Water ring vacuum pump version only (FAM-x-x-x-x/xxxx-x-x-x-S/SW-x-/x). In models with a rotary vane pump (FAM-x-x-x-x/xxxx-x-x-x-D-x-/x ), water is discharged from the vacuum pump as water vapor. Version FAM-x-x-x-x/xxxx-x-x-x-SW-x-/x HYDAC Filter Systems GmbH Page 25 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
The FAM continuously purifies the bypass fluid in the tank. Retransfer operation (only filtration). Only for versions with retransfer pump The medium is pumped through the filter from tank 1 to tank 2. HYDAC Filter Systems GmbH Page 26 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
(line) If the FAM is below the fluid surface in the tank, determine the pressure as follows: Δ Δ P = 1 bar + P(height) - (line) HYDAC Filter Systems GmbH Page 27 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 28
Make sure that no tension or vibrations are carried over to the pump or filter housing when the pipes are connected. Use hoses or expansion joints if necessary. HYDAC Filter Systems GmbH Page 28 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
To prevent air from entering the medium, make sure that the pressure hose with lance is always below the oil level in operation. HYDAC Filter Systems GmbH Page 29 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Adding Water Manually: Add clean tap water through the opening [N3.4] until the water level has reached the lower edge of the opening. Seal the opening again afterwards. HYDAC Filter Systems GmbH Page 30 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Page 31
The unit has a backflow preventer (1) as well as a filter combination (2). The backflow preventer (1) prevents unpurified water from flowing back into the connection. The backflow preventer (1) opens when the pressure falls under 1.5 bar HYDAC Filter Systems GmbH Page 31 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Synthetic vacuum pump oil in accordance with DIN 51506, Group VDL, ISO VG100 must be used for topping up. The vacuum pump oil can be ordered from HYDAC: Description Part no.: Vacuum pump oil VE101...
The suction strainer is re-mounted in reverse order. Retransfer pump (only for versions with retransfer pump, external pump) The differential pressure relief valve on the return pump is preset to 6 bar. HYDAC Filter Systems GmbH Page 34 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
A phase sequence relay checks the correct phase sequence after switch-on. In the event of an incorrect phase sequence, error message no. 29 is shown on the control panel. HYDAC Filter Systems GmbH Page 35 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
If too much foam is caused, it is drawn in by the vacuum pump. In this case, for example, reduce the vacuum from 350mbar to 450mbar. HYDAC Filter Systems GmbH Page 36 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
PressPress the "Mode" key to check the switching points. Press the arrow keys to change the switching point. The display automatically resets after 5 seconds without any action. HYDAC Filter Systems GmbH Page 37 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Use an Allen key wrench to carefully open the ventilation plug (A) in the cover for this purpose. It is not necessary to unscrew the ventilation plug (A) completely out – it contains air-vent slits. HYDAC Filter Systems GmbH Page 38 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Wait until the message appears on the display. Now move the main switch to the position "0". The system is now switched off. Ready for operation --> Press start HYDAC Filter Systems GmbH Page 39 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Acknowledge all rectified malfunctions. Button for special functions (depending on version) Select German language (or other languages depending on version). Select English language (or other languages depending on version). HYDAC Filter Systems GmbH Page 40 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
(Press the buttons one after the other) Exit With this key combination you can exit the Manual Menu This menu also switches itself off automatically after 15 minutes. HYDAC Filter Systems GmbH Page 41 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Opens the solenoid valve of the pump" vacuum pump Exit With this key combination you can exit the Manual Menu This menu also switches itself off automatically after 15 minutes. HYDAC Filter Systems GmbH Page 42 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Opens the water outlet of the vacuum pump Exit With this key combination you can exit the Manual Menu This menu also switches itself off automatically after 15 minutes. HYDAC Filter Systems GmbH Page 43 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Routine service and maintenance work is described in the documentation included: Maintenance and service instructions FAM-15/30/50/70", Document No.: 3168098 HYDAC Filter Systems GmbH Page 44 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Electric motor of the Switch on engine evacuation, feed, or protection in the electric Motor protection V-pump retransfer pump control, check operating Motor protection R-Pump overloaded viscosity Water ring vacuum HYDAC Filter Systems GmbH Page 45 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 46
Open shut-off devices in being pumped out of the suction line. FAM. Inlet (IN) clogged No fluid is being Open shut-off devices in pumped into the FAM suction line. HYDAC Filter Systems GmbH Page 46 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 47
Rotary vane vacuum pump: Drain oil. Fill level must be between min. and max. markings. No retransfer operation Retransfer operation not possible (no retransfer pump connected) HYDAC Filter Systems GmbH Page 47 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Excessive foaming -> vacuum in the vacuum chamber too high – reduce vacuum (e.g. from 300 mbar -> 400 mbar (abs) (abs) Check the evacuation pump for proper functioning The failure is repaired. HYDAC Filter Systems GmbH Page 48 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Replace level switch ->a. Function available -> proceed to Step 8. ->b. Function not available -> proceed to Step 9. The PLC is defective. Replace damaged parts HYDAC Filter Systems GmbH Page 49 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
->a. Fault appears again -> proceed to Step 5. ->b. The fault does not recur -> proceed to Step 6. Replace damaged parts The failure is repaired. HYDAC Filter Systems GmbH Page 50 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Check differential pressure switch and supply lines The failure is repaired. You can find details on changing the filter element in the maintenance and service instructions, document no. 3168098. HYDAC Filter Systems GmbH Page 51 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Does malfunction reappear after ≈ 2 seconds? ->a. Yes -> proceed to Step 7. ->b. No -> proceed to Step 8. Check float switch and supply lines The failure is repaired. HYDAC Filter Systems GmbH Page 52 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
-> proceed to Step 9. Check the operating viscosity of the medium (only for motor protection switch), perform maintenance work on the vacuum pump The failure is repaired. HYDAC Filter Systems GmbH Page 53 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
The failure is repaired. NOTICE Direction of rotation, electric motor The unit will be damaged ► After replacing electric motors, check the direction of rotation in manual operation before commissioning. HYDAC Filter Systems GmbH Page 54 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Tank to be cleaned is too small Check the functioning of vacuum pump in manual mode Find and remedy corresponding cause To reset the failure, press the RESET key The failure is repaired. HYDAC Filter Systems GmbH Page 55 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
-> proceed to Step 6. ->b. No -> proceed to Step 7. Check the pressure relief valve of the evacuation pump for proper functioning. The failure is repaired. HYDAC Filter Systems GmbH Page 56 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Check the suction pipe for cross-section constriction Check the functioning of vacuum pump in manual mode Check the position of the shut-off device in the suction line The failure is repaired. HYDAC Filter Systems GmbH Page 57 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Check SPS for proper -> proceed to Step 4. functioningThere may be too much foam in the vacuum chamber -> Reduce the vacuum The failure is repaired. HYDAC Filter Systems GmbH Page 58 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
2 hours, depending on ambient conditions. (A) = Temperature setting on the safety thermostat. (B) = Safety thermostat Reset button. Remedy: If this is not an inherited error, then proceed as follows: HYDAC Filter Systems GmbH Page 59 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
Page 60
F1 key ->a. The fault recurs -> proceed to Step 13. ->b. The failure does not recur -> proceed to Step 21. Contact the HYDAC Service Department The failure is repaired. HYDAC Filter Systems GmbH Page 60 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Regular inspection and maintenance work is indispensable for ensuring trouble-free operation and long service life for your FluidAqua Mobil. Our HYDAC Servicenter offers you these tasks within agreed-upon time frames and at fixed prices. HYDAC Service GmbH Rehgrabenstrasse 3 66128 Saarbrücken - Dudweiler...
Type label The type label is located on the front panel. Copy the data from the type label into the following, in order to have at hand when required. HYDAC Filter Systems GmbH Page 62 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc...
Standard - Water Ring Vacuum Pump Automatic water feed Rotary vane vacuum pump Instrumentation Without AquaSensor (AS) ContaminationSensor (CS) AquaSensor + ContaminationSensor Modification number Supplementary details Without details = standard HYDAC Filter Systems GmbH Page 63 / BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06...
FAM 15/30/50/70 EU declaration of conformity (only for mobile version) EU declaration of conformity (only for mobile version) HYDAC FILTER SYSTEMS GMBH Postfach 12 51 66273 Sulzbach / Saar Germany Industriegebiet 66280 Sulzbach / Saar Germany Telephone: ++49 (0) 6897 509 01 Internet: www.hydac.com...
Need help?
Do you have a question about the FluidAqua Mobil FAM 15 and is the answer not in the manual?
Questions and answers