A.4 Problems While Arming
A.4.1 Failure in Arming (When the Arming Process is Not Started)
Fault Description:
When the panel is arming, prompt arming fails.
Solution:
The panel does not enable "forced arming", and when there is a fault in the zone, the arming will
fail. Please turn on the "forced arming" enable, or restore the zone to the normal status.
A.5 Operational Failure
A.5.1 Failed to Enter the Test Mode
Fault Description:
Failed to enable test mode, prompting "A fault in the zone".
Solution:
Zone status, alarm status or zone power is abnormal.
A.5.2 The Alarm Clearing Operation on the Panel Does Not Produce the
Alarm Clearing Report
Fault Description:

The alarm clearing operation on the panel does not produce the alarm clearing report.

Solution:
In the absence of alarm, no report will be uploaded for arm clearing.
A.6 Mail Delivery Failure
A.6.1 Failed to Send Test Mail
Fault Description:
when configure the mail information, click "test inbox" and prompt test fails.