NOTICE
 When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described
below.
To prevent exposure to wind, install the outdoor unit
with its suction side facing the wall.
Never install the outdoor unit at a site where the
suction side may be exposed directly to wind.
To prevent exposure to wind, it is recommended to
install a baffle plate on the air discharge side of the
outdoor unit.
In heavy snowfall areas, select an installation site
where the snow will not affect the unit.
Figure 22
Bosch Climate 5000 Series Four Way Cassette Ductless Split Air Conditioner / Heat Pump (06.2022)
- Construct a large canopy.
- Construct a pedestal.
-
Install the unit high enough off the
ground to prevent burying in snow.

7.2 Install Drain Fitting

Heat pump units require a drain fi tting. Before bolting the outdoor unit in place,
you must install the drain fi tting at the bottom of the unit. Note that there are two
diff erent types of drain fi ttings depending on the type of outdoor unit.
If the drain fi tting comes with a rubber seal (see Figure 23, pos. A ), do the
following:
1.
Fit the rubber seal on the end of the drain fi tting that will connect to the
outdoor unit.
2.
Insert the drain fi tting into the hole in the base pan of the unit.
3.
Rotate the drain fi tting 90° until it clicks in place facing the front of the unit.
4.
Connect a drain hose extension (not included) to the drain fi tting to redirect
water from the unit during heating mode.
If the drain fi tting doesn't come with a rubber seal (see Figure 23, pos. B), do the
following:
1.
Insert the drain fi tting into the hole in the base pan of the unit. The drain
fi tting will click in place.
2.
Connect a drain hose extension (fi eld supplied) to the drain fi tting to
redirect water from the unit during heating mode.
NOTICE
 In cold climates, make sure that the drain hose is as vertical
as possible to ensure swift water drainage. If water drains
too slowly, it can freeze in the hose and flood the unit.
Seal
Seal
Drain fitting
(A)
Figure 23
Installation Instructions
Base pan hole of
outdoor unit
(B)
| 17