12.3.2 24k~48k models

Number
Display*
Error Information
1
EH 00/EH 0A
Indoor unit EEPROM parameter error
2
EL 01
Indoor / outdoor unit communication error
3
EH 03
The indoor fan speed is operating outside of the normal range(for some models)
4
EH 60
Indoor room temperature sensor T1 is in open circuit or has short circuited
5
EH 61
Evaporator coil temperature sensor T2 is in open circuit or has short circuited
6
EL 0C
Refrigerant Leakage Detection(for some models)
7
EH 0E
Water-level alarm malfunction
8
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short circuited
9
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short circuited
10
EC 54
Compressor discharge temperature sensor TP is in open circuit or has short circuited
11
EC 56
Evaporator coil outlet temperature sensor T2B is in open circuit or has short circuited(for free-match indoor units)
12
EC 51
Outdoor unit EEPROM parameter error
13
EC 07
The outdoor fan speed is operating outside of the normal range(for some models)
14
PC 00
IPM malfunction or IGBT over-strong current protection
15
PC 01
Over voltage or over low voltage protection
16
PC 02
Top temperature protection of compressor or High temperature protection of IPM module
17
PC 04
Inverter compressor drive error
18
PC 03
High pressure protection or low pressure protection (for some models)
19
EC 0d
Outdoor unit malfunction
20
--
Indoor units mode confl ict(match with multi outdoor unit)
Table 12
* The error codes are four digits, displayed two at a time on the LED.
For troubleshooting, please refer to the services manual.
Bosch Climate 5000 Series Four Way Cassette Ductless Split Air Conditioner / Heat Pump (06.2022)