  • Page 1 Bosch Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Climate 5000 Series Installation Manual...
  • Page 2 2 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 03.2019 | Bosch Thermotechnology Corp. Data subject to change...
  • Page 3: Table Of Contents

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 3 Table of Contents 1 Key to Symbols and Safety Instructions 1.1 Key to Symbols 1.2 Safety 2 Components 3 Installation Summary - Indoor Unit...
  • Page 4: Key To Symbols And Safety Instructions

    4 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 1 Key to Symbols and Safety Instructions 1.2 Safety Please read safety precautions before installation 1.1 Key to Symbols Incorrect installation due to ignoring instructions can cause serious damage or injury.
  • Page 5 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 5 WARNING: ELECTRICAL HAZARD CAUTION: CONTAINS REFRIGERANT  For all electrical work, follow all local and national wiring  This air-conditioning unit contains fluorinated gasses. For standards, regulations, and the Installation Manual.
  • Page 6: Components

    6 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 2 Components The air conditioning / heat pump system comes with the following components. Use all of the installation parts and components to install the air conditioner. Improper installation may result in water leakage, electrical shock and fi...
  • Page 7: Installation Summary - Indoor Unit

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 7 3 Installation Summary - Indoor Unit 15cm (5.9in) 12cm 12cm (4.75in) (4.75in) 230cm (90.55in) Select Installation Location Determine Wall Hole Position Attach Mounting Plate...
  • Page 8: System Components

    8 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 4 System Components Part Descriptions Indoor unit Indoor unit 1 Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6.
  • Page 9: Indoor Unit Installation

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 9 5 Indoor Unit Installation Refer to the following diagram (Fig. 3) to ensure proper distance from walls, ceiling and fl oor: Before installing the indoor unit, refer to the label on the product box to 15cm (5.9in) or more...
  • Page 10 1 0 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual Step 3: Drill wall hole for connective piping Mounting plate differences You must drill a hole in the wall for refrigerant piping, the drainage pipe, and the 429mm(16.88in)
  • Page 11 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 11 Step 4: Prepare refrigerant piping If there is no refrigerant piping embedded in the wall, do the following: Based on the position of the wall hole relative to the mounting plate, choose The refrigerant piping is inside an insulating sleeve attached to the back of the unit.
  • Page 12 1 2 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual Step 5: Connect drain hose By default, the drain hose is attached to the left-hand side of unit (when you’re facing the back of the unit). However, it can also be attached to the right-hand side.
  • Page 13 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 13 Step 6: Connect signal/power cable The signal/power cable enables communication between the indoor and outdoor units. You must fi rst choose the right cable size before preparing it for connection.
  • Page 14 1 4 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual Feed the signal wire through this slot, from the back of the unit to the front Facing the front of the unit, match the wire colors with the labels on the terminal block, connect the u-lug and and fi...
  • Page 15 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 15 If refrigerant piping is already embedded in the wall, do the following: Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
  • Page 16: Outdoor Unit Installation

    1 6 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 6 Outdoor Unit Installation Step 1: Select installation location Strong wind Before installing the outdoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.
  • Page 17 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 17 Step 2: Install drain joint Heat pump units require a drain joint. Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note that there are two diff...
  • Page 18 1 8 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual Step 3: Anchor outdoor unit The outdoor unit can be anchored to to a commercially available mounting pad on Outdoor Unit the ground or to a wall-mounted bracket (both sold separately).
  • Page 19 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 19 Step 4: Connect signal and power cables If you install the unit on a concrete mounting platform , do the following: The outside unit’s terminal block is protected by an electrical wiring cover on the Mark the positions for four expansion bolts based on dimensions in the Unit side of the unit.
  • Page 20 2 0 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual WARNING: ELECTRICAL HAZARD  Before performing an  y electrical or wiring work, turn off the main power to the system. Cover...
  • Page 21: Refrigerant Piping Connection

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 21 7 Refrigerant Piping Connection Step 2: Remove burrs Burrs can aff ect the air-tight seal of refrigerant piping connection. They must be completely removed.
  • Page 22 2 2 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual Step 4: Connect pipes Clamp fl aring block on the end of the pipe. The end of the pipe must extend beyond the edge of the fl...
  • Page 23: Connecting Piping To Indoor Unit

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 23 7.2 Connecting Piping to Indoor Unit 7.3 Connecting Tubing to Outdoor Unit Align the center of the two pipes that you will connect. See Figure 30.
  • Page 24: Air Evacuation

    2 4 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 8 Air Evacuation Wait for approximately 10 to 15 minutes, then check that there has been no change in system pressure. It is recommended to use a micron gauge; check 8.1 Preparations and Precautions...
  • Page 25: Adding Refrigerant

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 25 8.3 Adding Refrigerant In North America, the standard pipe length is 7.5m (25’). The additional refrigerant to be charged can be calculated using the following formula:...
  • Page 26: Electrical And Gas Leak Checks

    2 6 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 9 Electrical and Gas Leak Checks 9.2 Gas Leak Checks There are two diff erent methods to check for gas leaks.
  • Page 27: Test Run

    Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 27 10 Test Run WARNING: CONTAINS REFRIGERANT 10.1 Before Test Run  During operation, the pressure of the refrigerant circuit Only perform test run after you have completed the following steps: will increase.
  • Page 28: Disposal Guidelines

    2 8 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 11 Disposal Guidelines Components Many parts in the Air Conditioner can be fully recycled in the end of the product life. Contact your city authorities for information about the disposal of recyclable products.
  • Page 29 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 29 Bosch Thermotechnology Corp. | 03.2019 Data subject to change...
  • Page 30 3 0 | Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump Installation Manual 03.2019 | Bosch Thermotechnology Corp. Data subject to change...
  • Page 31 Installation Manual Bosch Climate 5000 Series Wall Mounted Ductless Single Split Air Conditioner / Heat Pump | 31 Bosch Thermotechnology Corp. | 03.2019 Data subject to change...
  • Page 32 United States and Canada Bosch Thermotechnology Corp. 65 Grove Street Watertown, MA 02472 Tel: 866-642-3198 Fax: 603-965-7581 www.boschheatingandcooling.com BTC 769003101 A /03.2019...