Rows of series installation
L
L ≤ H
L ≤ 1/2H
1/2H < L ≤ H
L > H
Cannot be installed
Table 6. The relations between H, A and L are as follows
H
Fig. 10.
NOTE:
The minimum distance between the outdoor unit and the walls described
in the installation guide does not apply to airtight rooms. Ensure to keep
the unit unobstructed in at least two of the three directions (M, N, P)
(See Fig. 11).
M
N
Fig. 11.
6.2
Drain Joint Installation
If the drain joint comes with a rubber seal (see Fig. 12 - A), do the
following:
1. Fit the rubber seal on the end of the drain joint that will connect to
the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks in place facing the front of
the unit.
4. Connect a drain hose extension (not included) to the drain joint to
redirect water from the unit during heating mode.
Climate 5000 MS – 6720887246 (2018/04)
If the drain joint doesn't come with a rubber seal (see Fig. 12 - B), do
the following:
A
1. Insert the drain joint into the hole in the base pan of the unit. The
25 cm or more
2. Connect a drain hose extension (not included) to the drain joint to
30 cm or more
Ensure the water drains to a safe location where it will not cause water
damage or become a slipping hazard.
L
A
Fig. 12.
6.3
You must drill a hole in the wall for the refrigerant piping and the signal
cable that will connect the indoor and outdoor units.
1. Determine the location of the wall hole based on the location of the
2. Using a 65-mm core drill, drill a hole in the wall.
When drilling the wall hole, ensure to avoid wires, plumbing, and other
sensitive components.
3. Place the protective wall cuff in the hole. This protects the edges of
6.4
P
When selecting 7.1KW units, the 7.1KW unit must be connected to
ports A on the condenser. When selecting two 7.1KW indoor units use
ports A & B. (See Fig. 13)
Table 7. Connective pipe size of an A and B system (unit: inch)
drain joint will click in place.
redirect water from the unit during heating mode.
NOTE:
Seal
Seal
Drain joint
(A)
Notes on Drilling Hole in Wall
outdoor unit.
NOTE:
the hole and helps seal it when you finish the installation process.
When Selecting 7.1KW units
Indoor Unit Capacity (KW)
2KW/2.6KW/3.5KW
5.3KW
7.1KW
Outdoor Unit Installation
Base pan hole of
outdoor unit
(B)
Liquid
Gas
1/4
3/8
1/4
1/2
3/8
5/8
9