Applicable Models : 9K - 18K - Bosch Climate 5000 Series Installation Instructions Manual

Four way cassette ductless split air conditioner / heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

5.2 Applicable Models : 9k - 18k

Refrigerant piping
545mm 21.5in (Susp. Bolt)
570mm 22.4in (Body)
647mm 25.5in (Panel)
70mm 2.8in
15mm 0.6in
600mm 23.6in (Ceiling opening)
or more
20mm 0.8in
Figure 6
>1m /
39.4in
Figure 7
Bosch Climate 5000 Series Four Way Cassette Ductless Split Air Conditioner / Heat Pump (06.2022)
Suspension Bolt
Hanger bracket
Drop ceiling
15mm 0.6in
or more
20mm 0.8in
>1m /
39.4in
Adjust the position to ensure the gaps between the indoor unit and the four sides of
drop ceiling are even. The indoor unit's lower part should sink into the drop ceiling
for 24mm / 0.9in.
1
2
1
Indoor unit
2
Drop ceiling
Figure 8
If the spacing between ceiling and the unit is over 20 mm / 0.8in, attach
sealing material in the part or recover the ceiling.