5. Jumper Settings

Jumper settings are applied to functions such as mainline-disconnect time, Start function,
transmitter push button layout, system information (serial number/ID code) programming and
system testing. The jumpers #1- #7 are located on the decoder module above the four (4) dip-
switches (refer to Fig.16 below).
Manufacture preset
Jumper Settings
JP3
(Blank)
JP3
(Inserted)
JP4
JP5
(Blank)
(Blank)
JP4
JP5
(Inserted)
(Blank)
JP4
JP5
(Blank)
(Inserted)
JP4
JP5
(Inserted)
(Inserted)
JP6
(Blank)
JP6
(Inserted)
JP7
(Inserted)
(Fig. 16)
After 1 or 3 minutes of transmitter inactivity (MAIN deactivated), press any
push button on the transmitter to reactivate the receiver MAIN.
After 1 or 3 minutes of transmitter inactivity (MAIN deactivated), rotate the
transmitter power key-switch to "START" position to reactivate the receiver
Standard right-to-left push button configuration for all models.
In-line push button configuration (top to bottom) for Flex 8ES/EX.
In-line push button configuration (top to bottom) for Flex 12ES/EX.
In-line push button configuration (top to bottom) for Flex 4ES/EX.
Program system serial number/ID code and channel from decoder module
Program system serial number/ID code and channel from I-CHIP
For system test only, receiver MAIN disabled.
Function
MAIN.
to I-CHIP.
to decoder module.
Flex 8EX EU System Instruction Manual
March 2012
24 of 37

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enrange Flex EX and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Enrange flex 8ex

Table of Contents