9. TABLE OF FUNCTIONS CONNECTED WIRED REMOTE CONTROL (RC-E5)
If wired remote control (option part) is connected to the following indoor units, some of the functions cannot be used. Please
see following table for details.
・Wall mounted type:SRK**ZSX-S, ZS-S
・Floor standing type:SRF**ZMX-S, ZMA-S
・Ceiling concealed type:SRR**ZM-S
NO.
Functions
1
Several remote controls for 1unit
2
Control of several indoor units
Plural control
3
Central control
4
5
Run/Stop
Change operation mode
6
Adjust fan speed
7
Auto swing of flap
8
Setting of air flow direction
9
10 Setting of temperture
11 Timer operation
Ventilation control
12
13
Display of unit number
Service switch-1: Display of error
14
data
Service switch -2 display of
15
operation data
16
Trial run
Forced operation of drain pump
17
Setting of compressor frequency
18
19
Quiet mode
Auto address change from remote
20
control
21
Indoor unit's address set of master
Filter reset
22
Clear memory of error code in
23
remote control
Clear memory of error code in the
24
indoor unit
Clear address in indoor unit
25
26
Reset CPU
27
Function setting
Setting of temperature range
28
External input
29
30
Auto adjustment of static pressure
Setting of static pressure
31
32
Filter sign
SRK
SRR
SRF
Indoor unit can be connected max. 2 remote controls.
One remote control can be connected toa max. of 16
indoor unit.
One outdoor unit can be connected to a max. of 4 indoor
×
×
units.
Signal of center mode from central control can be
restricted to operation of remote control.
Display of operation mode range is automatically decided
from the indoor unit's imformation.
Display of airflow range is automatically decided from the
indoor unit's imformation.
Display of air flow direction ON/OFF is automatically
×
decided from the indoor unit's imformation.
Setting of air flow direction for indoor unit that can be
×
×
×
changed air flow direction.
Sleep timer mode, Off timer mode, On timer mode,
Weekly timer mode.
Air infiltration can be controlled by the indoor unit that
×
×
×
has this function.
Display address number of remote control.
Display and memorize the error code data that are checked
finally.
Display operation data.
Cooling operation signal is sent to the indoor unit.
Forced operation of drain pump is sent to the indoor unit.
×
×
×
Fixing compressor frequency.
On timer in order to start quiet mode.
×
×
×
Auto address can be changed from remote control.
×
×
×
Adapt control for 3 pipe system.
×
×
×
Turning off signal display of filter sign and sending reset
×
×
×
signal of operating time.
Reset memory that remote control has the error code.
Reset memory of error for the indoor unit.
Reset memory of address for the indoor unit.
×
×
×
Reset outdoor or indoor CPU.
It is possible to set the function of remote control and
indoor unit.
Set Max and Min temperature.
External input from CnT terminal can be switched
between all unit operation and individual operation.
Change auto adjustment of static pressure.
×
×
×
Displayed part blinks on and off when it recives a
×
×
×
signal about auto adjustment of static pressure mode.
Displays filter sign via signal from indoor unit when
×
×
×
counting time achieves target time.
282
-
○:OK, △:Conditionally OK, ×:N/A
Outline of function
-
'17 • SCM-T-225
Remarks
Only SRK50,60ZSX-S
Flap control only. Louver cannot be controlled.
Temperture range can be set from 18 degree to
30 degree. Carving 0.5℃ is rounded up.
Warm up timer and sleep control of on timer
mode is impossible.
RAC unit does not have this function.
Address setted by SC-BIKN2-E for RAC
Only error code is used in the RAC unit.
RAC unit can be displayed some data.
RAC unit does not have this function.
RAC unit does not have this function.
RAC unit does not have this function.
RAC unit does not have this function.
RAC unit does not have this function.
RAC unit can be set a part of function.
For RAC models, only the range from 18℃ to
30℃ is available.
RAC unit does not have this function.
RAC unit does not have this function.
RAC unit does not have this function.