Mitsubishi Heavy Industries SCM71ZM-S1 Technical Manual page 275

Inverter multi-split system residential air-conditioners
Table of Contents

Advertisement

Error code
Remote control:
E47
1. Applicable model
All models
2. Error detection method
Error is displayed if the
converter voltage exceeds
DC340V (3 times within 20
minutes). Remote control
may be set after 3 minutes
delay.
3. Condition of error displayed
Same as above
4. Presumable cause
• Defective outdoor sub PCB
• Dust on outdoor sub PCB
• Anomalous power source
Note:
LED
Green
Red
Indoor Keeps flashing Stays OFF
2-time flash
Outdoor
5. Troubleshooting
Diagnosis
Is the power source normal?
YES
Is voltage
within the specified range?
YES
Check
soldered surfaces on the
outdoor sub PCB for foreign matter
like dust, fouling,
etc.
274
-
Content
Active filter voltage error
NO
NO
NO
YES
-
'17 • SCM-T-225
Countermeasure
Restore normal condition.
Restore normal condition.
Remove foreign matter like
dust, fouling, etc.
Defective outdoor sub PCB
➞ Replace.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents