Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Mitsubishi Heavy Industries Manuals
Air Conditioner
SCM71ZM-S1
Technical manual
E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control - Mitsubishi Heavy Industries SCM71ZM-S1 Technical Manual
Inverter multi-split system residential air-conditioners
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
Table Of Contents
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
page
of
379
Go
/
379
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Error code
E10
Remote control:
1. Applicable model
All models
2. Error detection method
When it detects more than 17 of
indoor units connected to one
remote contorl
3. Condition of error displayed
Same as above
4. Presumable cause
• Excessive number of indoor
units connected
• Defective remote control
Note:
LED
Green
Red
Keeps flashing Stays OFF
Indoor
–
Stays OFF
Outdoor
5. Troubleshooting
Diagnosis
Aren't more than 17
indoor units connected to one
remote control?
260
-
Excessive number of connected
Content
indoor units (more than 17 units)
by controlling with one remote control
NO
YES
-
'17 • SCM-T-225
Countermeasure
Defective remote control
➞ Replace.
Reduce to 16 or less units.
Table of
Contents
Previous
Page
Next
Page
1
...
260
261
262
263
Show Quick Links
Quick Links:
Table of Contents
E48 Outdoor Fan Motor Anomaly
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Mitsubishi Heavy Industries SCM71ZM-S1
Air Conditioner Mitsubishi Heavy Industries FDT100VNVF1 Technical Manual
Micro inverter packaged air-conditioners (554 pages)
Air Conditioner Mitsubishi Heavy Industries FDT Series Technical Manual
Hyper inverter packaged air-conditioners fdt, fdf, fdtc, fden, srk, fdc, fdum series (521 pages)
Air Conditioner Mitsubishi Heavy Industries FDT40VF Technical Manual
(519 pages)
Air Conditioner Mitsubishi Heavy Industries FDE40ZMXVG Technical Manual
Inverter packaged air-conditioners (476 pages)
Air Conditioner Mitsubishi Heavy Industries SCM50ZS-S1 Technical Manual
Inverter multi-split system residential air-conditioners (358 pages)
Air Conditioner Mitsubishi Heavy Industries SRK25ZM-S User Manual
(302 pages)
Air Conditioner Mitsubishi Heavy Industries FDT200VSAPVF1 Service Manual
Micro inverter packaged air conditioners (196 pages)
Air Conditioner Mitsubishi Heavy Industries SRR25ZJ-S Technical Manual
(174 pages)
Air Conditioner Mitsubishi Heavy Industries FDTC25VF Technical Manual
Inverter residential air conditioners (split system, air to air heat pump type) (112 pages)
Air Conditioner Mitsubishi Heavy Industries SRK60ZSX-S Technical Manual
Inverter wall mounted type residential air-conditioners, split system, air to air heat pump type (97 pages)
Inverter Mitsubishi Heavy Industries SRR25ZM-S Technical Manual
Inverter ceiling concealed type residential air-conditioners (90 pages)
Air Conditioner Mitsubishi Heavy Industries SCM40ZM-S Technical Manual
Inverter multi-split system residential air-conditioners (52 pages)
Air Conditioner Mitsubishi Heavy Industries SRK20ZS-S User Manual
(38 pages)
Air Conditioner Mitsubishi Heavy Industries SRR25ZM-S User Manual
(32 pages)
Air Conditioner Mitsubishi Heavy Industries SRF25ZMX-S User Manual
(17 pages)
Air Conditioner Mitsubishi Heavy Industries SRK20ZSX-S Technical Manual
Inverter wall mounted type residential air-conditioners (14 pages)
Related Content for Mitsubishi Heavy Industries SCM71ZM-S1
FDUA160AVSAVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDUA160AVSAVH
FDT200VSAWPVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT200VSAWPVH
FDT200VSAPVF1 E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT200VSAPVF1
FDTC25VH1 E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDTC25VH1
FDT100VNP1VF2 E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT100VNP1VF2
MHI FDU71VNXVF1 E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries MHI FDU71VNXVF1
FDT71VNXWVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT71VNXWVH
FDT100VNAWVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT100VNAWVH
FDT40ZSXW1VH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT40ZSXW1VH
SRR25ZJ-S E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries SRR25ZJ-S
SRK20ZJX-S E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Controller
Mitsubishi Heavy Industries SRK20ZJX-S
FDT71VNXWVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT71VNXWVH
FDT100VNAWVH E10 Excessive Number Of Connected Indoor Units (More Than 17 Units) By Controlling With One Remote Control
Mitsubishi Heavy Industries FDT100VNAWVH
FDC280KXZE1 Excessive Number Of Indoor Units (More Than 17 Units) By Controlling One Remote Control
Mitsubishi Heavy Industries FDC280KXZE1
KXZ Series Excessive Number Of Indoor Units By Controlling One Remote Control
Mitsubishi Heavy Industries KXZ Series
FDT Series Excessive Number Of Connected Indoor Units (More Than 17 Units)
Mitsubishi Heavy Industries FDT Series
This manual is also suitable for:
Scm80zm-s1
Srk20zsx-s
Srk25zsx-s
Srk35zsx-s
Srk50zsx-s
Srk60zsx-s
...
Show all
Srk20zs-s
Srk25zs-s
Srk35zs-s
Srk50zs-s
Srf25zmx-s
Srf35zmx-s
Srf50zmx-s
Srf25zma-s
Srf35zma-s
Srf50zma-s
Srr25zm-s
Srr35zm-s
Srr50zm-s
Srr60zm-s
Fdtc25vf
Fdtc35vf
Fdtc50vf
Fdtc60vf
Fden50vf
Fde50vg
Fdum50vf
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL