System 3000
Touch top unit
The extension operation in the "UP" direction (wind alarm) continues to be possible.
Touch surface (1) for longer than 4 seconds.
The status indication (5) flashes and the blind/shutter moves to the upper end position.
The status indication (5) flashes at the top for as long as the disabling function is active.
To deactivate the disabling function, touch surface (1) again for longer than 4 seconds.
Central control of blinds/shutters
For central operation the touch top unit can be placed on a Venetian blind insert that is connec-
ted to the extension terminals of one or multiple Venetian blind inserts.
Consider the following information:
The ventilation positions of the individual blinds/shutters deviate from each other as these
depend on the running times of the individual blinds/shutters.
The status indication of the central control can deviate from the actual blind/shutter posi-
tions.
6
Operation of lighting
The DALI-Power control unit flush-mounted insert behaves like a dimming insert. The col-
our temperature cannot be set at a DALI-Power control unit with a touch top unit.
Switching the light
Briefly touch several of the surfaces (1) to (4) simultaneously with the flat of your hand.
The light is switched on or off.
With dimming insert the light is switched on to brightness value 1.
Adjusting the brightness
The brightness can be set in different ways:
Briefly touch surface (1), (2) or (3).
Light switches to the corresponding saved brightness values.
Swipe slowly over surface (4) and release at the desired brightness.
The status indication (5) follows the touch. Light is set to the selected brightness.
Briefly touch surface (4) at the desired brightness.
Light is set to the selected brightness.
Saving the brightness values
A brightness value can be saved for each of the surfaces (1), (2) and (3). In the delivery state,
the values 25%, 50% and 75% are already stored. With every save the respective existing value
is overwritten.
Only surface (3) can also be used to switch off. For this, save the brightness value "Off".
Adjust the brightness.
Touch the desired surface for longer than 4 seconds.
Brightness value is saved. For confirmation, the light and the status indication (5) are
switched off briefly and switched on again.
When saving "Off" the light and status indication (5) are switched off briefly and switched
on again.
Operation with 3-wire extension with touch top unit
Precondition: A 3-wire extension with touch top unit is connected to the main device. The func-
tion of the extension varies from the function of the main device in the following points:
If the light is switched by briefly touching several of the surfaces (1) to (4) simultaneously,
the extension alternately sends the command "switch on" and "switch off" to the main
device. It may therefore occur, that it must be operated twice for the desired switching
state.