1.2.1
Default Jumper Settings
* indicates the default 0 Ω jumper installations for CRD5378.
Input Clock
EXTERNAL CLOCK
1.024 MHz
2.048 MHz
4.096 MHz
32.768 MHz
Table 2. System Clock Input Setting
DS639RD2
Amplifier
CS3301A
CH1
U19
R8 + R9
Table 1. Amplifier Pin 13 Jumper Setting
Resistor
R2
R70
R4
R3
*R60
Table 3. CS5378 PLL Mode Select Setting (R15, R41, R42)
Sync Source
RS-485
Direct Output
Table 4. Input SYNC Source Selection Setting
Sync Source
SYNC
SYNC_IO
Table 5. CS5378 SYNC Source Selection Setting
CS3302A
*R10
Digital Filter Clock
4.096 MHz Manchester
2.048 MHz Manchester
1.024 MHz Manchester
32.768 MHz
4.096 MHz
2.048 MHz
1.024 MHz
32.768 MHz
Jumper
*R47 + *R48
R49 + R50 + R45
Jumper
*R71 (Not Populated)
R71
CRD5378
Resistor
R15 + R41 + R42
R42
R41
R41+R42
R15
R15+R42
R15+R41
*Not Populated