Exdirt Magneto DN 200 - 400
1
Service flange with Exferro magnet insert
2
Drain valve (included in the accessory kit)
3
Magnesium sacrificial anode (optional for blanking plug)
4
Exferro magnet insert in immersion sleeve
5
Vent plug
6
Blanking plug
3

Technical data

Note!
The following values apply for all standard separators:
Max. temperature: 0-110 °C
Max. pressure: 10 bar
Special versions according to individual specification and nameplate.
Contact the manufacturer to determine the weight of the separator.
H
L (mm)
(mm)
DN 50
294
241
DN 65
344
261
DN 80
354
261
DN 100
358
261
DN 125
414
340.5
DN 150
414
340.5
DN 200
480
390.5
DN 250
546
484.7
DN 300
600
564.7
DN 400
550
614.7
4

Installation and assembly

CAUTION
Risk of burns
Escaping hot medium can cause burns.
Maintain a sufficient distance from the escaping medium.
Wear suitable personal protective equipment (safety gloves and
goggles).
4.1

Notes

The following items must be considered for assembly and installation of the
equipment:
Do not install the device above sensitive components or close to electrical
plant.
Perform installation in dry and frost-proof locations.
The flow direction is not specified.
The component can be installed horizontally or vertically.
D
Plug
(mm)
Brass
165
10.6
1"
185
12.9
1"
200
14.7
1"
220
16.4
1"
250
32.7
1 1/4"
285
36.5
1 1/4"
340
50.9
1 1/4"
405
81.2
1 1/4"
460
111.7
1 1/4"
580
156.5
1 1/4"
Exdirt magneto — 25.10.2022-Rev. B
2.1

Identification

Information on the type plate
XXX
Type
Connections
Max. allowable pressure
Max. allowable temperature
Year of manufacturing
Serial no.
Art.-No-
Ø
Magnet
Sacrificial
Sacrificial
insert
anode
anode
1
1
3/4"
1
1
3/4"
1
1
3/4"
1
1
3/4"
1
1
3/4"
1
1
3/4"
1
1
3/4"
2
1
3/4"
2
1
3/4"
3
1
3/4"
During installation ensure there are no residual stresses.
Any stresses that may occur in some cases must be countered by
appropriate constructive actions. Stresses may be caused by
temperature effects, for example.
Ensure the device is readily accessible in its installation location.
Ensure sufficient bearing capability of the installation site.
This applies to filling the separator with water in particular.
If necessary additional structural measures may be required to
ensure adequate load bearing capacity.
The device is not a load-bearing structural element.
By default, the calculation of the vessels does not take lateral
acceleration forces into account. Avoid alternating stresses such as
pressure shocks, abrupt pressure changes, or strong vibrations.
Use only approved transport and lifting equipment.
The angle of the lifting tackles must be maximum 60°.
After attachment of insulation, attach the additional sticker on the outside
so that it is readily visible.
Flush the system thoroughly after installation.
Meaning
Device name
Device type
Connection
Maximum permissible pressure
Maximum permissible temperature
Year of manufacturing
Serial number
Article number
Service flange
/ coupling
Female 2"
Female 2"
Female 2"
Female 2"
DN65
DN65
DN65
DN65
DN65
DN65
Technical data