SAFETY TESTS

E-STOP FUNCTION

With the projector operating and projectin laser light, press the E-stop switch. The projecor must shut
off immediately.
Fully extend the red E-stop switch, until a yellow collar is visible on the switch stem. The projector
must not emit any laser light.
Press the start button on E-stop box. The projector should now re-start and begin emitting laser light.
Verify that the emission indicator is now lit.

INTERLOCK RESET FUNCTION (POWER)

With the projector operating and projecting laser light, unplug the AC power cable. The projector
must shut off immediately.
Plug the power cable back in. The projector must not emit any laser light.
Press the start button on the E-stop box. The projector should now re-start and begin emitting laser
light.
Verify that the emission indicator is now lit.

KEY SWITCH FUNCTION

With the projector operating and projecting laser light, turn the key switch on the remote E-stop
control unit to off. The projector must shut off immediately.
Turn the key switch back to on. The projector must not emit any laser light.
Press the start button on the E-stop box. The projector should now re-start and begin emitting laser
light.
Verify that the emission indicator is now lit.
If any of the above tests fail, the projector must be taken out of service and returned to the manufacturer
for repair.