2.3

Setup display for User Defined view

Setup can only be made from a master RDU40. See "Two RDU40
connected to the same REX" on page 1-2.
Press the Back button until you reach the Main menu and choose
Display panel. A password is required - by default the password is blank
(just press OK) but the user can change it to prevent unauthorised users
from reconfiguring the RDU40.
Now the menu Display setup is shown. To start setup of the user
defined panel, choose User Defined and you arrive at Select items.
This is where you select which items (values) are to be shown. A
maximum of six items can be selected. If you wish to view the items in a
Two rows mode, the maximum is three. An item is selected (or
unselected) by moving the cursor down to it and then pressing the Mark
button. A tick in the corresponding square indicates the selected items.
24 items are available, of course dependent of how the REX gauge is
equipped:
Press Next to continue.
The next step is to Select mode, i.e. determine how the selected items
shall be shown. Select mode by moving the cursor to the desired mode
and press the Mark button. Three options are available:
Level
Ullage
Level rate
Signal strength
Volume
Average temperature
Temperature spot 1 - 6
Analog input 1-2
Vapor pressure
Liquid pressure
Vapor temperature
Observed density
Free water level
Hart slave 1-3
Relay 1-2
Rosemount Tank Radar REX