Tapered Pipe Thread Fittings - MacDon D1 XL Series Assembly Instructions Manual

Draper header for windrower
Table of Contents

Advertisement

8.1.7 Tapered Pipe Thread Fittings

The proper method of assembling a pipe thread fitting is:
1. Check components to ensure that fitting and port threads are free of burrs, nicks and scratches, or any form of
contamination.
2. Apply pipe thread sealant (paste type) to the external pipe threads.
3. Thread the fitting into the port until hand-tight.
4. Torque the connector to the appropriate torque angle. The Turns From Finger Tight (TFFT) values are shown
8.10 Hydraulic Fitting Pipe Thread, page
in Table
(typically 45º or 90º) is aligned to receive the incoming tube or hose assembly. Always finish alignment of fitting
in the tightening direction. Never back off (loosen) pipe threaded connectors to achieve alignment
5. Clean all residue and any excess thread conditioner with the appropriate cleaner.
6. Assess the final condition of the fitting. Pay special attention to the possibility of cracks to the port opening.
7. Mark the final position of the fitting. If a fitting leaks, disassemble the fitting and check for damage.
NOTE:
*Over-torque failure of fittings may not be evident until the fittings are disassembled.
Table 8.10 Hydraulic Fitting Pipe Thread
Tapered Pipe
Recommended
Thread Size
1/8–27
1/4–18
3/8–18
1/2–14
3/4–14
1–11 1/2
1 1/4–11 1/2
1 1/2–11 1/2
2–11 1/2
214017
Recommended
T.F.F.T
F.F.F.T
2–3
12–18
2–3
12–18
2–3
12–18
2–3
12–18
1.5–2.5
12–18
1.5–2.5
9–15
1.5–2.5
9–15
1.5–2.5
9–15
1.5–2.5
9–15