Page 1
CC8 Series pumps are covered 24 months by warranty within the limits mentioned in our General Sales Conditions. In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX, warranty will be canceled.
When requested, they can be delivered with a 8 bar spring adjusted at the maximum pressure of use. Temperature range allowed : -20°C à +80°C Products authorised : Contact us NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 3/19...
• Tight the nut. • Check on the installation the pump gives the right pres- sure (using a manometer) with a closed valve on the discharge line. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 6/19...
REMINDER : You cannot rely on the coupling to compensate for mis- alignment. NEVER START A UNIT IF THE COUPLING ALIGNMENT IS INCORRECT. THIS WILL RENDER OUR WARRANTY INVALID. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 7/19...
TY DAMAGE OR DEATH. Do not operate without guard in place. 6. DRIVE BY POWER TAKE OFF Refer to Instructions NT 1010-B00 CC8 CC10 CC20 PUMPS RIVEN BY POWER TAKE OFF NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 8/19...
In the case of liquids containing particles settling on shut-down, it is necessary to make sure the consistency of the deposit will not impede restarting the pump. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 9/19...
• Stop the pump and make sure no liquid is coming back > pump has to be closed. Step 2 : • Defect or in complement, drain by the bottom plug. Drain plug NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 10/19...
Before any dismantling, make sure that the pump has been drained and take all the necessary precautions to prevent it from star- ting up. The pump must not start up, even accidentally. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 11/19...
Screw up the 2 screws at the same time so that the end- plate is gradually released along the centre line. When the end-plate is free on the shaft, hold it by hand supporting it. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 12/19...
Refit the vanes (new if necessary) respecting the direction of assembly. Reassemble the pump and check that it rotates freely when turned by hand. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 13/19...
101. Re-fit the end plate on the non-drive side (see § REASSEMBLY OF THE PUMP). Check that the pump rotates freely when turned by hand. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 14/19...
Clean all parts before reassembly. Reassemble in reverse order of dismantling. Set bypass at initial pressure setting by tightening nut with the same number of rotations as counted during dismounting. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 15/19...
Change when "h" < to 31,0 29,0 CC8-40 31,0 29,0 CC8-50 DIMENSIONS OF THE PUSHRODS - mm Pump Original lenght "L" Change when "L" < to 82,5 82,0 CC8-40 85,0 84,5 CC8-50 NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 16/19...
- Pump damaged (see § Abnormal noise - Pump damaged due to passage of foreign matter). • Bypass valve hammer on its seat due to incorrect adjustment of the spring’s tension. NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 17/19...
The pump must be scrapped in compliance with the regulations During this operation, particular care must be paid to the drai- in force. nage stages of the pump (pumped product). NT 1010-E00 03 18 CC8-40 AP - CC8-50 AP pumps e 18/19...
Need help?