Page 1
S Series pumps are covered 24 months by warranty within the limits mentioned in our General Sales Conditions. In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX, warranty will be canceled.
1 - 2 - 3 - 4 Discharge 1 - 2 - 3 - 4 This position of the mounting bracket does not permit orientation of the discharge in position 4. Dimensions in millimetres NT 1002-B00 07 19 S4C Pump e 3/15...
Suction pipe configuration Check tightness to avoid accidental air intake. 2.1.1 Pump To obtain the service expected from a MOUVEX pump, regarding both performance and longevity, it is vital that the type of pump, its speed and the materials used for its construction are determined as a function of the pump output, its installation and operating conditions.
2.3 Direction of rotation be avoided or equipped with drain valve. The S4C pump only has one rotation direction (the pump not being reversible), clockwise (observer facing the back of the pump).
The following instructions apply to pumps delivered with use the values given on the overall dimension drawing). a bare shaft or for MOUVEX motor-driven pump units (if the latter have no specific instruction notice). For staff and equipment protection, the frame includes a ground connection point that should be used.
Page 7
Using electric motors is very common now; however, we strongly advise careful reading of the accompanying ins- truction manual. NT 1002-B00 07 19 S4C Pump e 7/15...
A compressor effect close to 3 bar is obtained for a period of 3 minutes. After that, the value falls to 0.5 bar as the lubrication ensured by the pumped product rapidly disap- pears from between the piston and the cylinder. NT 1002-B00 07 19 S4C Pump e 8/15...
Although a particular care was taken to clean- liness when assembling the pump, we recom- The CIP pump must be installed in series with the S4C mend to carry out a cleaning of the pump before pump (see fig. 1) or the couple piston/cylinder risks any use.
Figure 4 CIP Pump S4C Pump Indeed, in this case, the pressure at entry to the S4C pump is lower than the exit pressure and the piston remains stuck against the cylinder. The S4C pump is not flushed through. Its good cleaning is therefore no longer ensured and the cylin- der/piston couple will be prematurely worn.
101). then the hand nut 311. Re-mount the base 401 and the seal 205 taking care to give the discharge port the desired angular position. ® Loctite is a registered trademark. NT 1002-B00 07 19 S4C Pump e 12/15...
(1,142) As changes in the pump's efficiency depend on the conditions of use (pressure, rotation speed, liquid pum- ped, etc.), MOUVEX recommends that users define the monitoring ranges and the preventive maintenance schedule according to their own experience. d : measured distance 6.2 Checking of seals...
• Etc. Do not attempt to remove the sleeve or to empty the oil MOUVEX pumps and motor-driven pumps are well lubri- from it. This operation can only be done in the factory. cated when delivered to protect the internal parts during If in doubt, replace the complete transmission.
Need help?
Do you have a question about the S4C and is the answer not in the manual?
Questions and answers