Mouvex SLS24 i Installation Operation & Maintenance

Mouvex SLS24 i Installation Operation & Maintenance

Eccentric piston pump

Advertisement

SLS24 i - SLS36 i
PUMPS
:
,
1528,
."
INSTRUCTIONS 1004-H00 e
Section
1004
Effective
October 2016
Replaces
June 2016
Original instructions
INSTALLATION
OPERATION
MAINTENANCE
" 3, e .5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLS24 i and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mouvex SLS24 i

  • Page 1 INSTRUCTIONS 1004-H00 e Section 1004 Effective October 2016 Replaces June 2016 Original instructions SLS24 i - SLS36 i PUMPS INSTALLATION OPERATION MAINTENANCE 1528, ." " 3, e .5...
  • Page 2: Table Of Contents

    = 9 bar • Pump stopped, the pressure must not exceed 6 barg (87 psig). - Acceptable maximal differential pressure : • SLS24 i ..9 bar (130,5 psi)* Page TABLE OF CONTENTS • SLS36 i ..6 bar (87 psi)* - Maximum pressure jacket : 5 barg (72,50 psig) 1.
  • Page 3: Overall Dimensions

    1. OVERALL DIMENSIONS NT 1004-H00 10 16 SLS24 i - SLS36 i e 3/29...
  • Page 4 1. OVERALL DIMENSIONS (continued) NT 1004-H00 10 16 SLS24 i - SLS36 i e 4/29...
  • Page 5 1. OVERALL DIMENSIONS (continued) NT 1004-H00 10 16 SLS24 i - SLS36 i e 5/29...
  • Page 6 1. OVERALL DIMENSIONS (continued) NT 1004-H00 10 16 SLS24 i - SLS36 i e 6/29...
  • Page 7 1. OVERALL DIMENSIONS (continued) NT 1004-H00 10 16 SLS24 i - SLS36 i e 7/29...
  • Page 8: Installation

    Check tightness to avoid accidental air intake. Recommended Suction pipe length Length should be as short as possible. -------------------------------------------------------------------- R = 3 x D minimum L = 10 x D minimum NT 1004-H00 10 16 SLS24 i - SLS36 i e 8/29...
  • Page 9: Orientation Of The Pump Ports

    The bellows may be damaged and lead to premate failure. • The bearing must be ventilate at all times, therefore the breather mounted on the bearing must be re-used. Never put the plug on. NT 1004-H00 10 16 SLS24 i - SLS36 i e 9/29...
  • Page 10: Hoisting Devices

    (if it is made of concrete, foreign bodies by mounting a pre-filter at the pump suc- it must comply with the BAEL 91 standard). tion. NT 1004-H00 10 16 SLS24 i - SLS36 i e 10/29...
  • Page 11 To control the alignment between the coupling and the shaft, use a straight-edge for concentricity and thickness gauges for angular misalignment (see instructions of the coupling for authorised values). NT 1004-H00 10 16 SLS24 i - SLS36 i e 11/29...
  • Page 12 Three-phase motor : switch any 2 current input wires. Bi-phase motor : switch two same phase wires. Single-phase motor : follow the instructions on the notice supplied with the motor. NT 1004-H00 10 16 SLS24 i - SLS36 i e 12/29...
  • Page 13: Utilisation

    For any pure water pumping during process or cleaning operations, consult Mouvex imperatively. NT 1004-H00 10 16 SLS24 i - SLS36 i e 13/29...
  • Page 14: Clean In Place (Cip) & Sterilisation In Place (Sip)

    The bypass valve is adjusted to divide the flow bet- cous products). It can be reduced for easier types of ween the circuit flowing through the SLS Series pump cleaning. and the bypass circuit. NT 1004-H00 10 16 SLS24 i - SLS36 i e 14/29...
  • Page 15: Pumps Arranged In Parallel

    Cleaning the installation : SLS Series pump SLS Series pump The pump must not run during this operation. The SLS Series pump is stopped when cleaning the ins- tallation. NT 1004-H00 10 16 SLS24 i - SLS36 i e 15/29...
  • Page 16: Successive Cycles

    • M8 : 18 Nm • 13-32 Open-end spanner • M16 : 100 Nm • Hub puller • M24 : 200 Nm • 85 Open-end spanner or Monkey wrench NT 1004-H00 10 16 SLS24 i - SLS36 i e 16/29...
  • Page 17: Opening Of The Pump

    • Disconnect the pump from the discharge pipe. • Unscrew the 8 nuts 106 and remove the 8 tierods 105 and 107. • Remove the outlet tube 402 and its seals 205. NT 1004-H00 10 16 SLS24 i - SLS36 i e 17/29...
  • Page 18: Checking Of Parts

    • With the help of a hub puller, extract the piston 301. • Small steps at piston wall base (B). • Remove the cylinder 201 and the seals 113 and 306. NT 1004-H00 10 16 SLS24 i - SLS36 i e 18/29...
  • Page 19 Piston must then look as follows : disc wall edges. Even if it shows wearing signs, do not retouch any surface of the cylinder by any mean as it can degrade pump performance and reliability. NT 1004-H00 10 16 SLS24 i - SLS36 i e 19/29...
  • Page 20: Assembly Of Cylinder/Piston

    BE CAREFUL WITH THE WEIGHT OF THE PARTS WHEN THEY ARE BEING REMOVED. The weight ot the parts can be dangerous and may provoke bodily injuries or material damages. Loctite ® is a registered trademark. NT 1004-H00 10 16 SLS24 i - SLS36 i e 20/29...
  • Page 21: Protection Of The Bellows

    117 and 513. The nuts 115 must be re-mounted with thread locking adhesive (Loctite ® 243* or equivalent) : 4 x M16 : Assembly torque 100 Nm. Loctite ® is a registered trademark. NT 1004-H00 10 16 SLS24 i - SLS36 i e 21/29...
  • Page 22 We advise leaving this protection around the bellows until remounting of the piston and cylinder. DO NOT FORGET TO REMOVE THE PROTECTION BEFO- RE MOUNTING THE CYLINDER. NT 1004-H00 10 16 SLS24 i - SLS36 i e 22/29...
  • Page 23: Changing The Lip Seal

    • If the seal face is marked, change the ring 507. Break the ring with a chisel then fit a new ring after heating it at 90°C (in an oil bath or at HF). * Standard oils provided by MOUVEX (Safety data sheet is supplied on inquiery) : CS05 Food synthetic oil CS23 Silicone free oil for transmission * Other oil provided by customer.
  • Page 24: Changing The Orientation Of The Ports

    • Replace the 8 tierods 107 and tighten the nuts 106. • Make sure that the seal 205 is secured in its housing. Secure it with a grease that is compatible with the transferred product if necessary. NT 1004-H00 10 16 SLS24 i - SLS36 i e 24/29...
  • Page 25: Draining Of Bearing

    • Check oil level that the level is between 1 and 5 mm above the shaft. • Screw back the breather 715. * Standard oils provided by MOUVEX (Safety data sheet is supplied on inquiery) : CS05 Food synthetic oil CS23 Silicone free oil for transmission * Other oil provided by customer.
  • Page 26: Storage

    This protection should also prevent condensation. The pump should be turned a few revolutions manually every two months. NT 1004-H00 10 16 SLS24 i - SLS36 i e 26/29...
  • Page 27: Troubleshooting

    (the piston bushings are worn, worn piston and cylinder, broken piston wear compensation springs, worn partition, broken shaft). NT 1004-H00 10 16 SLS24 i - SLS36 i e 27/29...
  • Page 28 (faulty alignment, deformation of the chassis, stress exerted by the piping on the flanges, seizing, etc.). Excessive consumption of electricity can also be due to a poor motor connection (e.g. a 3 phase motor operating on 2 phases). NT 1004-H00 10 16 SLS24 i - SLS36 i e 28/29...
  • Page 29: Certificate Of Conformity

    15. CERTIFICATE OF CONFORMITY NT 1004-H00 10 16 SLS24 i - SLS36 i e 29/29...

This manual is also suitable for:

Sls36 iC4 aC4 a htC8 aC8 a ht

Table of Contents