Page 1
Section 1001 Effective October 2010 Replaces August 2010 Original instructions C12 A - C18 A PUMPS INSTALLATION OPERATION MAINTENANCE Your distributor : Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE Tel. : +33 (0)3.86.49.86.30 - Fax : +33 (0)3.86.49.87.17...
AND PROPERTY DAMAGE. Hazardous pressure can cause The following instructions apply to pumps delivered with personal injury a bare shaft or for MOUVEX motor-driven pump units (if or property damage. the latter have no specific instruction notice). 2.5.1 INSTALLATION OF UNITS CAUTION...
Page 8
The motors should be protected with circuit breakers and suitable fuses. Connect the regulatory electrical grounding. NT 1001-F00 10.10 C12 A - C18 A e 8/20...
The C series pump is self priming and is capable of emp- conditions without the drive is less than 81 dB(A). tying the pipes. To do this, it can run dry for a maximum duration of 5 minutes. NT 1001-F00 10.10 C12 A - C18 A e 9/20...
PARTS WHEN THEY ARE BEING REMOVED. SPILLS MUST BE CLEANED UP. The weight ot the parts can Slippery lubricant. be dangerous and may Spills should be provoke bodily injuries or cleaned up. material damages. NT 1001-F00 10.10 C12 A - C18 A e 10/20...
• With the help of a hub puller, extract the piston 301. • Remove the front cover 401 with its seal 205. • Remove the cylinder 201 and the seals 113, 306 and 307. NT 1001-F00 10.10 C12 A - C18 A e 11/20...
Piston Cylinder mm (inch) mm (inch) New dimension (0,354) (1,969) Minimum wear dimension acceptable (0,236) (1,850) New dimension (0,354) (2,756) Minimum wear dimension acceptable (0,236) (2,638) NT 1001-F00 10.10 C12 A - C18 A e 12/20...
• Screw the 6 screws 106 (6 x M16 assembly torque 100 Nm). ® • Place thread locking adhesive (Loctite 243* or equivalent) on the thread of the transmission hub 596. Loctite ® is a registered trademark. NT 1001-F00 10.10 C12 A - C18 A e 13/20...
The screws 111 must be re-mounted with thread locking adhesive (Loctite ® 243* or equivalent) : 4 x M16 : Assembly torque 100 Nm. Loctite ® is a registered trademark. NT 1001-F00 10.10 C12 A - C18 A e 14/20...
95°C (in an oil bath or at HF). • Place a new seal 518. * Standard oil provided by MOUVEX : CS05 Food synthe- tic oil (Safety data sheet is supplied with the new pump and on inquiery).
804 (do not remove any associated parts). • Remove the spring 804. • Replace spring 804 and carry out reassembly in rever- se order of disassembly. NT 1001-F00 10.10 C12 A - C18 A e 16/20...
• Remove the 4 screws 132 from the main body 101 as well as the main body plate 131 and the seal 130. • Reassembly is in reverse order of disassembly. NT 1001-F00 10.10 C12 A - C18 A e 17/20...
Oil level Min : 1 mm Max : 5 mm * Standard oil provided by MOUVEX : CS05 Food synthe- tic oil (Safety data sheet is supplied with the new pump and on inquiery). * Other oil provided by customer.
Any puncture in either one of the two metallic bellows leads to a pressure drop. When the pressure decrease under the pressure switch setting, it cuts the electrical circuit. To connect the electrical pressure switch, follow the manufacturer instruction. NT 1001-F00 10.10 C12 A - C18 A e 19/20...
Quality Manager MOUVEX sas : Z.I La Plaine des Isles – 2, rue des Caillottes - 89000 AUXERRE – France – SAS au capital de 8 496 855 € Tél : (33) 3.86.49.86.30 – Fax : (33) 3.86.46.42.10 – RCS AUXERRE 389 236 548 – APE 291 B – FR 85 389 236 548 – www.mouvex.com...
Need help?
Do you have a question about the C12 A and is the answer not in the manual?
Questions and answers