Motor Modules Booksize
4.2 Motor modules booksize internal air cooling
Meaning of the LEDs on the motor module
Table 4-5
Meaning of the LEDs on the motor module
LED
Color
-
Green
Orange
READY
Red
Green
Red
-
Orange
DC LINK
Red
Cause and rectification of faults
The following reference contains information about the cause and rectification of faults:
Reference: /IH1/ SINAMICS S120, Installation and Start-Up Manual
4-10
State
Description
OFF
Electronics power supply outside permissible tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
Continuous
At least one fault is present in this component.
Flashing
The firmware is being downloaded.
2 Hz
Component recognition via LED is activated (p0124).
OFF
Electronics power supply outside permissible tolerance range.
Continuous
DC link voltage within permissible tolerance range (only when ready
for operation).
Continuous
DC link voltage outside permissible tolerance range (only when ready
for operation).