Line connection
The active line module is rated for the voltage range 3AC 380 V -10% to
3AC 480 V +10% (-15% < 1min) at 47 Hz to 63 Hz.
Table 3-1
Connection methods active line module
Terminals
Line connection
Active line modules
16 kW
36 kW
55 kW
80 kW to 120 kW
1) For ring cable lugs to DIN 46234
2) See Connection methods
X200-X202 DRIVE-CLiQ interfaces
Table 3-2
DRIVE-CLiQ interface X200-X202
PIN
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
Booksize Power Sections
Equipment Manual, (GH2), 04.2004 Edition, 6SL3097-2AC00-0BP0
Designations
X1 (U1, V1, W1)
Screw terminal 10 mm
Threaded hole for PE: M5/3 Nm
Threaded bolt M6/6 Nm
Threaded hole for PE: M6/3 Nm
Threaded bolt M8/13 Nm
Threaded hole for PE: M6/6 Nm
Threaded bolt M8/13 Nm
Threaded hole for PE: M8/6 Nm
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
3.2 Active line modules booksize internal air cooling
3–pin / 1.5 Nm
2
2)
1)
1)
1)
1)
1)
1)
1)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
24 V power supply
Electronic ground
Line Modules Booksize