Siemens SINAMICS S120 Equipment Manual page 63

Booksize power sections
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Internal air cooling
Rated power
DC link
capacitance
Charging limit
Power factor
Efficiency
Cooling method
Cooling air requirement
Sound pressure level
Weight
*Values valid for 380 V and not 380 V – 10%.
Rated duty cycles of active line modules
P
P
max
P
s6
P
n
0.4 Pn
10 min
S6 duty cycle with prior loading
P
P
max
P
n
0.2 s
10 s
Peak power duty cycle with prior loading
Figure 3-8
Rated duty cycles of active line modules
Booksize Power Sections
Equipment Manual, (GH2), 04.2004 Edition, 6SL3097-2AC00-0BP0
6SL3130–
7TE21–
6AAx
kW
16
μF
705
μF
20 000
cosϕ
1
η
0.95
Internal fan Internal fan Internal fan Separate
m
/h
56
3
dB(A)
<60
Rated voltage for rated data 3 AC 380 V
kg
7
P
max
P
s6
P
n
4 min
0.4 Pn
t
t
P
max
P
n
t
t
3.2 Active line modules booksize internal air cooling
7TE23–
7TE25–
6AAx
5AAx
36
55
1 410
1 880
20 000
20 000
1
1
0.95
0.95
112
160
<65
<60
10.3
17
P
10 s
60 s
Peak power duty cycle with prior loading
P
4 s
10 s
Peak power duty cycle without prior loading
Line Modules Booksize
7TE28–0AAx
7TE31–2AAx
80
120
2 820
3 995
20 000
20 000
1
1
0.95
0.95
Separate
mounted fan
mounted fan
520
520
<75
<75
23
23
t
t
3-15