Table 6–2
QSIO circuit pack (A6 and B6) options – part number: NT6M60BA
Device type
(number)
DIP
1 On channel A select
Switch
(S6)
2 On channel B select
3 On channel C select
4 On channel D select
Note: Baud rate selection for the four DPP channels is made at the four rotary switches (S2, S3,
S4, and S5) on the front of the circuit pack. The baud rate selected can be for a synchronous
channel or an asynchronous channel. The following chart provides the conversion for
asynchronous to synchronous baud rates and the rotary switch position for the applicable selection.
Switch
position
0
1
2
3
4
5
6
7
Rotary
0
50
Switch
1
75/1200
(S2)
2
110
3
134.5
4
150/2400
5
300/4800
6
600/9600
7
1200
Rotary
0
50
Switch
1
75/1200
(S3)
2
110
3
134.5
4
150/2400
5
300/4800
6
600/9600
7
1200
Position/setting
Off (normal setting)
Off (normal setting)
Off (normal setting)
Off (normal setting)
Asynch
Synch
rate
50
75
110
134.5
150
300
600
1200
8
1800
9
2000
A
2400
B
3600
C
4800
D
7200
E
9600
F
19200
8
1800
9
2000
A
2400
B
3600
C
4800
D
7200
E
9600
F
19200
(continued)
Function
NOT USED.
Switch
rate
position
800
8
1200
9
1760
A
2152
B
2400
C
4800
D
9600
E
7
19200
F
BX.25 Polling Link
(Synchronous channel;
2400 baud)
Channel A baud rate se-
lect.
7
MMI Link
(Asynchronous chan-
nel; 2400 baud)
Channel B baud rate
select.
7
DPP Card Replacement Guide BCS35 and up
QSIO circuit pack 57
(continued)
Setting
Factory
On–site
Off
Off
Off
Off
Asynch
Synch
rate
rate
1800
2000
2400
3600
4800
7200
9600
7
19200
4
(2400 baud)
(This switch is inac-
tive for DPP systems
with 56K polling.)
A
(2400
baud)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Need help?
Do you have a question about the BCS35 and is the answer not in the manual?