4.8.3 No working function
with multiple
actuation
Fault
Function only at consumer with
lowest pressure demand
Insufficient function at one
consumer

4.8.4 Consumers lower

Fault
Internal leak at the directional
control valve too high

4.8.5 Oil heating-up

Fault
System pressure build-up in neutral
position
Circulation pressure too high

4.8.6 External oil leaks

Fault
Oil leak between plates
Oil leak at solenoid
Oil leak at pressure pilot valve unit
Oil leak at screw plug
10/04
QUANTUM
Cause
Pump oil delivery too low
Non-return valve in load
signalling line leaking as it
does not close its ball or its
ball is missing
Ram of directional control
valve works stiffly
Cause
Control spool or valve body
worn
Cause
Incorrect valve mounting
plate, no control oil return
Z - T
Directional control valve
does not return fully to the
neutral position as
connecting screws are
tightened too much (30 Nm)
Cause
Sealing plate damaged
Foreign object between O-
ring and seal surface
Seal surface damaged,
possibly due to a blow on
the edge
Sealing damaged
Sealing nut not locked or
cutting edge of drain plug
damaged
Sealing nut damaged
Screw plug loose
Copper seal damaged
Hydraulics
Remedy
Replace or clean pump
Install ball if missing
Remove and clean
Remedy
Replace directional
control valve
Remedy
Replace plate
Reduce tightening torque
Remedy
Replace
Clean
Dress surface
Replace
Tighten or replace
Replace
Tighten
Replace