Faults And Remedies; Control System (Lp/Lm08 With Sv02) - Claas QUANTUM 3500 Service Parts

Technical systems
Table of Contents

Advertisement

TIC
4.8
Faults and
remedies
4.8.1 Control system
(LP/LM08 with
SV02)
With open hydraulic system:
Tractor system pressure or
170 bar pressure build-up
with deactivated control units
With oil supply from "John
Deere tractors": Steering
"wanders"
Hydraulic motor – does not
run
Hydraulic motor – runs only
in one direction
Hydraulic motor – does not
stop
Hydraulic motor – does not
reach max. speed
Cylinder – no function
Cylinder – does not remain
pressure-tight
No function from any
cylinder
No function from cylinders or
motor
Oil heating up
External leaks
Eliminating the faults
10/04
QUANTUM
a
System screw turned in
b
System screw turned out
c
Control spool jams
d
Nozzle plugged
e
Pressure valve will not close
f
Insufficient electric power supply
g
Pressure reducer works stiffly
h
Control spool works stiffly
i
Electric contact is not interrupted
k
Solenoid will not switch
l
Seated valve will not close
m
Hydraulic motor defective
n
Sealing plate, sealing nut or O-ring defective
o
Block twisted, tie rods tightened too much
Circulation valve with
pressure relief valve
a
b
c
d
1
2
3
3
1
1
Back off screw
2
Turn in screw
3
Remove and clean
4
Check electric system, operate emergency shut-off
5
Insufficient electric power supply or pump capacity too low
6
Electric contact not interrupted, remove plug
7
Replace valve block
8
Replace
9
Check tie rod tightening torque (30 Nm)
Directional control
valve
e
f
g
h
i
4
3
3
3
6
5
4
3
Hydraulics
Seated
valve
k
l
m
n
o
8
4
7
8
9
11-99