No Working Function Lp/Lm08 - Claas QUANTUM 3500 Service Parts

Technical systems
Table of Contents

Advertisement

Hydraulics
4.8.2 No working function
LP/LM08
Fault
No or insufficient pressure
build-up in all consumers
System pressure build-up
Oil supply to one consumer
is too low or too high
Oil supply to all consumers
too low
Oil supply to valve with the
largest flow range is not
achieved
One consumer has no
function
Various valves switch
irregularly
11-100
QUANTUM
Cause
Spool of circulation/pressure relief valve
jams
Pressure pilot control valve does not close
because of
Foreign object between seat and
ball
Valve seat pressed out
O-ring of pressure pilot valve unit
damaged
Orifice plate in spool of
circulation/pressure relief valve
clogged
Operating pressure is higher than
preset safety pressure
3 way directional control valve
connected as 4 way valve
Incorrect control spool installed
Electric power supply not correct
Pump oil delivery too low
Solenoid is not switching
Spool of pressure reduction valve
jams
Control spool works stiffly
Control spool works stiffly
Remedy
Clean
Check tie rod tightening
torque (30 Nm)
Remove and clean
Replace pressure pilot
valve unit
Replace O-ring
Clean
Increase pressure setting
Replace valve
Replace spool
Check electric controller
Check pump and suction
line
Check electric system
Check solenoid
Remove and clean
Remove and clean
Remove and clean
Check tie rod tightening
torque (30 Nm)
TIC
10/04